Study of the corrosion resistance and in vitro biocompatibility of PVD TiCN-coated AISI 316 L austenitic stainless steel for orthopedic applications

被引:95
作者
Antunes, R. A. [1 ]
Rodas, A. C. D. [2 ]
Lima, N. B. [2 ]
Higa, O. Z. [2 ]
Costa, I. [2 ]
机构
[1] Fed Univ ABC UFABC, Engn Modeling & Appl Social Sci Ctr CECS, BR-09210170 Santo Andre, SP, Brazil
[2] IPEN CNEN SP, BR-05508900 Sao Paulo, Brazil
关键词
TiCN coating; PVD; 316; L; Corrosion; Biomaterial; MECHANICAL-PROPERTIES; ELECTRONIC-STRUCTURE; PASSIVE FILMS; COATINGS; BEHAVIOR; TIN; TITANIUM; MULTILAYER; ACID; WEAR;
D O I
10.1016/j.surfcoat.2010.08.101
中图分类号
TB3 [工程材料学];
学科分类号
082905 [生物质能源与材料];
摘要
The aim of the present work was to study the corrosion resistance in Hanks' solution and the in vitro biocompatibility of a TiCN-coated AISI 316 L stainless steel. The electrochemical behavior was assessed using potentiodynamic polarization and electrochemical impedance spectroscopy. Cytotoxicity and genotoxicity tests were performed to evaluate the potential biocompatibility of the specimens. TiCN morphology was investigated using scanning electron microscopy (SEM). Bare 316 L specimens were also evaluated for comparison. The results showed that the film morphology strongly influences the electrochemical behavior of the coated underlying metal. TiCN-coated specimens presented neither cytotoxicity nor genotoxicity. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2074 / 2081
页数:8
相关论文
共 49 条
[1]
[Anonymous], [No title captured]
[2]
[Anonymous], THESIS U SAO PAULO
[3]
[Anonymous], 109933 ISO
[4]
[Anonymous], METHODS XRAY CRYSTAL
[5]
[Anonymous], IECD GUID TEST CHEM
[6]
[Anonymous], POWD DIFFR FIL
[7]
[Anonymous], 2002, MET FINISH
[8]
Corrosion-wear behaviour of PVD Cr/CrN multilayer coatings for gear applications [J].
Bayon, R. ;
Igartua, A. ;
Fernandez, X. ;
Martinez, R. ;
Rodriguez, R. J. ;
Garcia, J. A. ;
de Frutos, A. ;
Arenas, M. A. ;
de Damborenea, J. .
TRIBOLOGY INTERNATIONAL, 2009, 42 (04) :591-599
[9]
Composition, structure and properties of the oxide films formed on the stainless steel 316L in a primary type PWR environment [J].
Belo, MD ;
Walls, M ;
Hakiki, NE ;
Corset, J ;
Picquenard, E ;
Sagon, G ;
Noel, D .
CORROSION SCIENCE, 1998, 40 (2-3) :447-463
[10]
Chemical composition and semiconducting behaviour of stainless steel passive films in contact with artificial seawater [J].
Belo, MD ;
Rondot, B ;
Compere, C ;
Montemor, MF ;
Simoes, AMP ;
Ferreira, MGS .
CORROSION SCIENCE, 1998, 40 (2-3) :481-494