An Embolic Deflection Device for Aortic Valve Interventions

被引:116
作者
Nietlispach, Fabian [1 ]
Wijesinghe, Namal [1 ]
Gurvitch, Ronen [1 ]
Tay, Edgar [1 ]
Carpenter, Jeffrey P. [2 ]
Burns, Carol [3 ]
Wood, David A. [4 ]
Webb, John G. [1 ]
机构
[1] St Pauls Hosp, Dept Cardiol, Vancouver, BC V6Z 1Y6, Canada
[2] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Camden, NJ 08103 USA
[3] Embrella Cardiovasc Inc, Wayne, PA USA
[4] Vancouver Gen Hosp, Vancouver, BC, Canada
关键词
cerebral embolism; cerebral protection; Embrella Embolic Deflector; percutaneous aortic valve replacement; stroke; TAVI; CAROTID ANGIOPLASTY; CARDIOPULMONARY BYPASS; CEREBRAL PROTECTION; HEART-VALVE; RISK; VALVULOPLASTY; IMPLANTATION; IMPACT; SILENT; CATHETERIZATION;
D O I
10.1016/j.jcin.2010.05.022
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Objectives We describe initial human experience with a novel cerebral embolic protection device. Background Cerebral emboli are the major cause of procedural stroke during percutaneous aortic valve interventions. Methods With right radial artery access, the embolic protection device is advanced into the aortic arch. Once deployed a porous membrane shields the brachiocephalic trunk and the left carotid artery deflecting emboli away from the cerebral circulation. Embolic material is not contained or removed by the device. The device was used in 4 patients (mean age 90 years) with severe aortic stenosis undergoing aortic balloon valvuloplasty (n = 1) or transcatheter aortic valve implantation (n = 3). Results Correct placement of the embolic protection device was achieved without difficulty in all patients. Continuous brachiocephalic and aortic pressure monitoring documented equal pressures without evidence of obstruction to cerebral perfusion. Additional procedural time due to the use of the device was 13 min (interquartile range: 12 to 16 min). There were no procedural complications. Pre-discharge cerebral magnetic resonance imaging found no new defects in any of 3 patients undergoing transcatheter aortic valve implantation and a new 5-mm acute cortical infarct in 1 asymptomatic patient after balloon valvuloplasty alone. No patient developed new neurological symptoms or clinical findings of stroke. Conclusions Embolic protection during transcatheter aortic valve intervention seems feasible and might have the potential to reduce the risk of cerebral embolism and stroke. (J Am Coll Cardiol Intv 2010;3:1133-8) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 29 条
[1]
A randomized trial of carotid artery stenting with and without cerebral protection [J].
Barbato, Joel E. ;
Dillavou, Ellen ;
Horowitz, Michael B. ;
Jovin, Tudor G. ;
Kanal, Emanuel ;
David, Suzanne ;
Makaroun, Michel S. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (04) :760-765
[2]
Occurrence and clinical impact of microembolic signals during or after cardiosurgical procedures [J].
Dittrich, Ralf ;
Ringelstein, E. Bernd .
STROKE, 2008, 39 (02) :503-511
[3]
Duffis Ennis J, 2007, Expert Rev Cardiovasc Ther, V5, P1113, DOI 10.1586/14779072.5.6.1113
[4]
Eisenhauer AC, 2000, CATHETER CARDIO INTE, V50, P484, DOI 10.1002/1522-726X(200008)50:4<484::AID-CCD25>3.0.CO
[5]
2-W
[6]
Cerebral injury during cardiopulmonary bypass: Emboli impair memory [J].
Fearn, SJ ;
Pole, R ;
Wesnes, K ;
Faragher, EB ;
Hooper, TL ;
McCollum, CN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (06) :1150-1160
[7]
Cerebral Protection Devices Reduce Periprocedural Strokes During Carotid Angioplasty and Stenting: A Systematic Review of the Current Literature [J].
Garg, Nitin ;
Karagiorgos, Nikolaos ;
Pisimisis, George T. ;
Sohal, Davendra P. S. ;
Longo, G. Matthew ;
Johanning, Jason M. ;
Lynch, Thomas G. ;
Pipinos, Iraklis I. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (04) :412-427
[8]
Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation A Prospective Pilot Study With Diffusion-Weighted Magnetic Resonance Imaging [J].
Ghanem, Alexander ;
Mueller, Andreas ;
Naehle, Claas P. ;
Kocurek, Justine ;
Werner, Nikos ;
Hammerstingl, Christoph ;
Schild, Hans H. ;
Schwab, Joerg O. ;
Mellert, Fritz ;
Fimmers, Rolf ;
Nickenig, Georg ;
Thomas, Daniel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) :1427-1432
[9]
GROSSETETE R, 1989, ANN RADIOL, V32, P97
[10]
Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76