LED Fluorescence Microscopy for the Diagnosis of Pulmonary Tuberculosis: A Multi-Country Cross-Sectional Evaluation

被引:56
作者
Cuevas, Luis Eduardo [1 ,2 ]
Al-Sonboli, Najla [3 ]
Lawson, Lovett [4 ]
Yassin, Mohammed Ahmed [1 ]
Arbide, Isabel [5 ]
Al-Aghbari, Nasher [3 ]
Sherchand, Jeevan Bahadur [6 ]
Al-Absi, Amin [7 ]
Emenyonu, Emmanuel Nnamdi [4 ]
Merid, Yared [8 ]
Okobi, Mosis Ifenyi [9 ]
Onuoha, Juliana Olubunmi [4 ]
Aschalew, Melkamsew [8 ]
Aseffa, Abraham [10 ]
Harper, Greg [1 ]
de Cuevas, Rachel Mary Anderson [1 ]
Theobald, Sally Jane [1 ]
Nathanson, Carl-Michael [2 ]
Joly, Jean [2 ]
Faragher, Brian [1 ]
Squire, Stephen Bertel [1 ]
Ramsay, Andrew [2 ]
机构
[1] Univ Liverpool, Liverpool Sch Trop Med, Liverpool L3 5QA, Merseyside, England
[2] World Hlth Org Special Programme Res & Training T, World Bank, United Nations Dev Programme, United Nations Childrens Fund, Geneva, Switzerland
[3] Sanaa Univ, Fac Med, Sanaa, Yemen
[4] Zankli Med Ctr, Abuja, Nigeria
[5] Bushullo Major Hlth Ctr, Awasa, Ethiopia
[6] Tribhuvan Univ, Inst Med, Kathmandu, Nepal
[7] Natl TB Inst, Sanaa, Yemen
[8] So Reg Hlth Bur, Awasa, Ethiopia
[9] Wuse Gen Hosp, Abuja, Nigeria
[10] Armauer Hansen Res Inst, Addis Ababa, Ethiopia
基金
比尔及梅琳达.盖茨基金会;
关键词
TECHNOLOGIES;
D O I
10.1371/journal.pmed.1001057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The diagnosis of tuberculosis (TB) in resource-limited settings relies on Ziehl-Neelsen (ZN) smear microscopy. LED fluorescence microscopy (LED-FM) has many potential advantages over ZN smear microscopy, but requires evaluation in the field. The aim of this study was to assess the sensitivity/specificity of LED-FM for the diagnosis of pulmonary TB and whether its performance varies with the timing of specimen collection. Methods and Findings: Adults with cough >= 2 wk were enrolled consecutively in Ethiopia, Nepal, Nigeria, and Yemen. Sputum specimens were examined by ZN smear microscopy and LED-FM and compared with culture as the reference standard. Specimens were collected using a spot-morning-spot (SMS) or spot-spot-morning (SSM) scheme to explore whether the collection of the first two smears at the health care facility (i.e., "on the spot") the first day of consultation followed by a morning sample the next day (SSM) would identify similar numbers of smear-positive patients as smears collected via the SMS scheme (i.e., one on-the-spot-smear the first day, followed by a morning specimen collected at home and a second on-the-spot sample the second day). In total, 529 (21.6%) culture-positive and 1,826 (74.6%) culture-negative patients were enrolled, of which 1,156 (49%) submitted SSM specimens and 1,199 (51%) submitted SMS specimens. Single LED-FM smears had higher sensitivity but lower specificity than single ZN smears. Using two LED-FM or two ZN smears per patient was 72.8% (385/529, 95% CI 68.8%-76.5%) and 65.8% (348/529, 95% CI 61.6%-69.8%) sensitive (p<0.001) and 90.9% (1,660/1,826, 95% CI 89.5%-92.2%) and 98% (1,790/1,826, 95% CI 97.3%-98.6%) specific (p<0.001). Using three LED-FM or three ZN smears per patient was 77% (408/529, 95% CI 73.3%-80.6%) and 70.5% (373/529, 95% CI 66.4%-74.4%, p<0.001) sensitive and 88.1% (95% CI 86.5%-89.6%) and 96.5% (95% CI 96.8%-98.2%, p<0.001) specific. The sensitivity/specificity of ZN smear microscopy and LED-FM did not vary between SMS and SSM. Conclusions: LED-FM had higher sensitivity but, in this study, lower specificity than ZN smear microscopy for diagnosis of pulmonary TB. Performance was independent of the scheme used for collecting specimens. The introduction of LED-FM needs to be accompanied by appropriate training, quality management, and monitoring of performance in the field.
引用
收藏
页数:10
相关论文
共 18 条
[1]  
Aziz M., 2002, EXTERNAL QUALITY ASS
[2]  
Cattamanchi A, 2009, INT J TUBERC LUNG D, V13, P1130
[3]   A Multi-Country Non-Inferiority Cluster Randomized Trial of Frontloaded Smear Microscopy for the Diagnosis of Pulmonary Tuberculosis [J].
Cuevas, Luis Eduardo ;
Yassin, Mohammed Ahmed ;
Al-Sonboli, Najla ;
Lawson, Lovett ;
Arbide, Isabel ;
Al-Aghbari, Nasher ;
Sherchand, Jeevan Bahadur ;
Al-Absi, Amin ;
Emenyonu, Emmanuel Nnamdi ;
Merid, Yared ;
Okobi, Mosis Ifenyi ;
Onuoha, Juliana Olubunmi ;
Aschalew, Melkamsew ;
Aseffa, Abraham ;
Harper, Greg ;
de Cuevas, Rachel Mary Anderson ;
Kremer, Kristin ;
van Soolingen, Dick ;
Nathanson, Carl-Michael ;
Joly, Jean ;
Faragher, Brian ;
Squire, Stephen Bertel ;
Ramsay, Andrew .
PLOS MEDICINE, 2011, 8 (07)
[4]   The future looks bright:: low-cost fluorescent microscopes for detection of Mycobacterium tuberculosis and Coccidiae [J].
Hanscheid, Thomas .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2008, 102 (06) :520-521
[5]  
IUATLD, 2000, TECHN GUID SPUT EX T
[6]   Reducing the global burden of tuberculosis: the contribution of improved diagnostics. [J].
Keeler E. ;
Perkins M.D. ;
Small P. ;
Hanson C. ;
Reed S. ;
Cunningham J. ;
Aledort J.E. ;
Hillborne L. ;
Rafael M.E. ;
Girosi F. ;
Dye C. .
Nature, 2006, 444 (Suppl 1) :49-57
[7]   Improvement of tuberculosis case detection and reduction of discrepancies between men and women by simple sputum-submission instructions: a pragmatic randomised controlled trial [J].
Khan, Mishal Sameer ;
Dar, Osman ;
Sismanidis, Charalambos ;
Shah, Karam ;
Godfrey-Faussett, Peter .
LANCET, 2007, 369 (9577) :1955-1960
[8]  
Klatser P, 2010, INT J TUBERC LUNG D, V14, P377
[9]   Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum [J].
Marais, Ben J. ;
Brittle, Wendy ;
Painczyk, Katrien ;
Hesseling, Anneke C. ;
Beyers, Nulda ;
Wasserman, Elizabeth ;
van Soolingen, Dick ;
Warren, Rob M. .
CLINICAL INFECTIOUS DISEASES, 2008, 47 (02) :203-207
[10]  
Mase SR, 2007, INT J TUBERC LUNG D, V11, P485