Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions

被引:146
作者
Dueck, MH
Klimek, M
Appenrodt, S
Weigand, C
Boerner, U
机构
[1] Univ Cologne, Dept Anesthesiol, D-50924 Cologne, Germany
[2] Univ Cologne, Dept Otolaryngol, D-50924 Cologne, Germany
[3] Erasmus Univ, Med Ctr, Dept Anesthesiol, Rotterdam, Netherlands
关键词
D O I
10.1097/00000542-200508000-00007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Previous studies found contradictory results regarding the question whether mixed venous oxygen saturation (Svo(2)) and central venous oxygen saturation (Scvo(2)) are equivalent. The inconsistency of study results may result from different study designs and different, partly questionable, statistical approaches. Methods: The authors performed a prospective clinical trial comparing individual oxygen saturation values as well as the trend of values in blood from the superior vena cava (Scvo(2)), the right atrium (Srao(2)), and the pulmonary artery (Svo(2)) during varying hemodynamic situations. The subjects were 70 patients scheduled to undergo elective neurosurgical operations in the sitting position. Oxygen saturation was measured photospectrometrically in blood samples simultaneously taken at four different time points during supine and sitting positions. Statistical analysis was performed following the recommendations of Bland and Altman. Results: Five hundred two comparative sets of measurements were obtained. Ninety-five percent limits of agreement ranging from +/- 6.83 to +/- 9-30% for single values were interpreted as clinically unacceptable. in contrast, correlations between changes of Svo(2) and Scvo(2) as well as of Svo(2) and Srao(2) were interpreted as clinically acceptable (R >= 0.755, Pearson correlation coefficient; P <= 0.0001). Conclusions: In this sample of patients, exact numerical values of Scvo(2) and Srao(2) are not equivalent to those of Svo(2) in varying hemodynamic conditions. However, for clinical purposes, the trend of Scvo(2) may be substituted for the trend of Svo(2). In addition, previous studies investigating the agreement between Svo(2) and Scvo(2) were found to be lacking in their chosen statistical approaches.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 40 条
[1]  
BAILEY PL, 2000, INTRAVENOUS OPIOID A, P273
[2]  
BARRATTBOYES BG, 1957, J LAB CLIN MED, V50, P93
[3]   INFLUENCE OF CARDIAC-OUTPUT ON THE CORRELATION BETWEEN MIXED VENOUS AND CENTRAL VENOUS OXYGEN-SATURATION [J].
BERRIDGE, JC .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (04) :409-410
[4]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Effects of the sitting position on the distribution of blood volume in patients undergoing neurosurgical procedures [J].
Buhre, W ;
Weyland, A ;
Buhre, K ;
Kazmaier, S ;
Mursch, K ;
Schmidt, M ;
Sydow, M ;
Sonntag, H .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (03) :354-357
[7]  
CANO BM, 1996, AN ESP PEDIATR, V44, P149
[8]   Lack of equivalence between central and mixed venous oxygen saturation [J].
Chawla, LS ;
Zia, H ;
Gutierrez, G ;
Katz, NM ;
Seneff, MG ;
Shah, M .
CHEST, 2004, 126 (06) :1891-1896
[9]  
CONNORS JR, 1999, JAMA-J AM MED ASSOC, V276, P889
[10]   CARDIORESPIRATORY EFFECTS OF THE SITTING POSITION IN NEUROSURGERY [J].
DALRYMPLE, DG ;
MACGOWAN, SW ;
MACLEOD, GF .
BRITISH JOURNAL OF ANAESTHESIA, 1979, 51 (11) :1079-1082