Microfluidic devices for cellomics: a review

被引:538
作者
Andersson, H
van den Berg, A
机构
[1] Univ Twente, MESA Inst, NL-7500 AE Enschede, Netherlands
[2] Royal Inst Technol, Dept Signals Sensors & Syst, S-10044 Kista, Sweden
[3] Silex Microsyst AB, S-16440 Kista, Sweden
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2003年 / 92卷 / 03期
关键词
cellomics; microfluidic devices; lab-on-chip;
D O I
10.1016/S0925-4005(03)00266-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A review of microfluidic devices for cellomics is presented. After a brief description of the historical background of Lab-on-Chip (LOC) devices, different areas are reviewed. Devices for cell sampling are presented, followed by cell trapping and cell sorting devices based upon mechanical and electrical principles. Subsequently, a popular type of cell sorters, flow cytometers, is considered, followed by a chapter describing devices for cell treatment: cell lysis, poration/gene transfection and cell fusion devices. Finally a number of microfluidic devices for cellular studies are reviewed. The large amount of very recent publications treated in this review indicates the rapidly growing interest in this exciting application area of LOC. (C) 2003 Elsevier Science B.V All rights reserved.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 98 条
[1]   Micromachined flow-through filter-chamber for chemical reactions on beads [J].
Andersson, H ;
van der Wijngaart, W ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :203-208
[2]  
AUROUX P, 1974, ANAL CHEM, V74, P2637
[3]  
BAKAJIN O, 1998, FRANCTIONATION MIXIN, P193
[4]   SEPARATION OF HUMAN BREAST-CANCER CELLS FROM BLOOD BY DIFFERENTIAL DIELECTRIC AFFINITY [J].
BECKER, FF ;
WANG, XB ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
GASCOYNE, PRC .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (03) :860-864
[5]   A minisonicator to rapidly disrupt bacterial spores for DNA analysis [J].
Belgrader, P ;
Hansford, D ;
Kovacs, GTA ;
Venkateswaran, K ;
Mariella, R ;
Milanovich, F ;
Nasarabadi, S ;
Okuzumi, M ;
Pourahmadi, F ;
Northrup, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4232-4236
[6]   Modular concept of a laboratory on a chip for chemical and biochemical analysis [J].
Blankenstein, G ;
Larsen, UD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :427-438
[7]   Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology [J].
Cai, XX ;
Klauke, N ;
Glidle, A ;
Cobbold, P ;
Smith, GL ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :908-914
[8]   Self-sorting of white blood cells in a lattice [J].
Carlson, RH ;
Gabel, CV ;
Chan, SS ;
Austin, RH ;
Brody, JP ;
Winkelman, JW .
PHYSICAL REVIEW LETTERS, 1997, 79 (11) :2149-2152
[9]  
CHANG W, 2002, CELL SEPARATION TRAN, P820
[10]   A multichannel neural probe for selective chemical delivery at the cellular level [J].
Chen, JK ;
Wise, KD ;
Hetke, JF ;
Bledsoe, SC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (08) :760-769