Amperometric Quantification of Gluten in Food Samples Using an ELISA Competitive Assay and Flow Injection Analysis

被引:16
作者
Amaya-Gonzalez, Sonia [1 ]
de-los-Santos-Alvarez, Noemi [1 ]
Jesus Lobo-Castanon, Maria [1 ]
Miranda-Ordieres, Arturo J. [1 ]
Tunon-Blanco, Paulino [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
33-mer peptide; ELISA competitive assay; Electrochemical detection; Gluten; Gliadin; DISEASE TOXIC GLIADIN; CELIAC-DISEASE; IMMUNOSENSOR; IMMUNOASSAY; PEPTIDE;
D O I
10.1002/elan.201000583
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Gluten analysis in food is intricate because of the analyte variability among cereal species and protein states. Herein the immunodominant peptide 33-mer from alpha2-gliadin is proposed as standard for calibration in a competitive ELISA assay with amperometric flow-injection detection. Using the monoclonal antibody G12, a correlation between the content of gluten in peptide and gluten units was obtained for the first time. The analytical features were compared with optical measurements using several standards obtaining a slightly lower detection limit, which suggested the sensitivity is limited by affinity and not by the detection technique. "Gluten-free" samples were satisfactorily analyzed.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 14 条
[1]
[Anonymous], RIDASCREEN GLIADIN C
[2]
Codex Alimentarius Commission, 2006, 27 SESS COD COMM MET
[3]
Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat [J].
Crew, A. ;
Alford, C. ;
Cowell, D. C. C. ;
Hart, J. P. .
ELECTROCHIMICA ACTA, 2007, 52 (16) :5232-5237
[4]
Measurement of gluten using a monoclonal antibody to a coeliac toxic peptide of A gliadin [J].
Ellis, HJ ;
Rosen-Bronson, S ;
O'Reilly, N ;
Ciclitira, PJ .
GUT, 1998, 43 (02) :190-195
[5]
Increasing prevalence of coeliac disease over time [J].
Lohi, S. ;
Mustalahti, K. ;
Kaukinen, K. ;
Laurila, K. ;
Collin, P. ;
Rissanen, H. ;
Lohi, O. ;
Bravi, E. ;
Gasparin, M. ;
Reunanen, A. ;
Maeki, M. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2007, 26 (09) :1217-1225
[6]
Sensitive detection of cereal fractions that are toxic to celiac disease patients by using monoclonal antibodies to a main immunogenic wheat peptide [J].
Moron, Beln ;
Cebolla, Angel ;
Manyani, Hamid ;
Alvarez-Maqueda, Moises ;
Megias, Manuel ;
Thomas, Maria del Carmen ;
Lopez, Manuel Carlos ;
Sousa, Carolina .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2008, 87 (02) :405-414
[7]
Electrochemical Immunosensor for Detection of Celiac Disease Toxic Gliadin in Foodstuff [J].
Nassef, Hossam M. ;
Redondo, M. Carmen Bermudo ;
Ciclitira, Paul J. ;
Ellis, H. Julia ;
Fragoso, Alex ;
O'Sullivan, Ciara K. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9265-9271
[8]
Amperometric Immunosensor for Detection of Celiac Disease Toxic Gliadin Based on Fab Fragments [J].
Nassef, Hossam M. ;
Civit, Laia ;
Fragoso, Alex ;
O'Sullivan, Ciara K. .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5299-5307
[9]
Homogeneous stopped-flow fluorimmunoassay for gliadin determination in food samples [J].
Sánchez-Martínez, ML ;
Aguilar-Caballos, MP ;
Gómez-Hens, A .
ANALYTICA CHIMICA ACTA, 2004, 523 (01) :35-41
[10]
SKERRITT JH, 1991, J ASSOC OFF ANA CHEM, V74, P257