We have designed, built, and tested microfluidic systems capable of transporting individual, preimplantation mouse embryos (100-mum to 150-mum diameter) through a network of channels. Typical channels are 160 to 200 mum deep, 250 to 400 mum wide at the top, and narrower at the bottom (0 to 250 mum wide) due to the fabrication process, In these channels, a pressure gradient of 1 Pa/mm causes the medium to flow on the order of 10(-10) m(3)/s (100 nl/s), with an average speed of 1 to 2 mm/s, Under these flow conditions the embryos roll along the bottoms of the channels, traveling at 1/2 the speed of the fluid, By manipulating the pressure at the wells connected to the ends of the channels, the embryos can be transported to land retained at) specific locations including culture compartments and retrieval wells.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 31 条
[1]   Microfabrication-based ektacytometer for blood cell deformability measurements [J].
Altendorf, E .
MICRO- AND NANOFABRICATED ELECTRO-OPTICAL MECHANICAL SYSTEMS FOR BIOMEDICAL AND ENVIRONMENTAL APPLICATIONS, PROCEEDINGS OF, 1997, 2978 :136-144
[2]  
AYLIFFE H, 1997, P 1997 INT C SOL STA, P1307
[3]   Culture of preimplantation embryos: Facts and artifacts [J].
Bavister, BD .
HUMAN REPRODUCTION UPDATE, 1995, 1 (02) :91-148
[4]   THE ANATOMY AND PHYSIOLOGY OF PRE-ATTACHMENT BOVINE EMBRYOS [J].
BETTERIDGE, KJ ;
FLECHON, JE .
THERIOGENOLOGY, 1988, 29 (01) :155-187
[5]  
Bird R. B., 1960, TRANSPORT PHENOMENA, P129
[6]   Activation and Sorting of Human White Blood Cells [J].
Carlson, Robert H. ;
Gabel, Chris ;
Chan, Shirley ;
Austin, Robert H. .
BIOMEDICAL MICRODEVICES, 1998, 1 (01) :39-47
[7]   Development of an embryo transport and analysis system: Material biocompatability [J].
Chan, NG ;
Lyman, JT ;
Choi, SJ ;
Zeringue, HC ;
Glasgow, IK ;
Beebe, DJ ;
Wheeler, MB .
THERIOGENOLOGY, 1999, 51 (01) :234-234
[8]  
Choi SJ, 1998, BIOL REPROD, V58, P96
[9]   An array of hollow microcapillaries for the controlled injection of genetic materials into animal/plant cells [J].
Chun, K ;
Hashiguchi, G ;
Toshiyoshi, H ;
Fujita, H ;
Kikuchi, Y ;
Ishikawa, J ;
Murakami, Y ;
Tamiya, E .
MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, :406-411
[10]  
EASLEY KD, 1997, J ANIM SCI, V75, P64