Automated system for power measurement in the silent discharge

被引:32
作者
Feng, R
Castle, GSP
Jayaram, S
机构
[1] Univ Western Ontario, Dept Elect Engn, London, ON N6A 5B9, Canada
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
关键词
AC discharge; corona discharge; ozone generator; power measurement; silent discharge;
D O I
10.1109/28.673727
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
With the increased interest in improving the conversion efficiency of the silent discharge for ozone generation, there is a need for an accurate and convenient technique to measure the power consumed. Normally, the power consumption of an ac silent discharge is measured by using a wattmeter on the low-voltage side of the input transformer. However, this measurement includes the transformer losses, which generally are nonlinear and may account for a significant proportion of the total power loss. Alternatively, the power loss in the silent discharge alone may be calculated by means of results obtained from the oscillograms of the charge-versus-voltage (q-v trace) method or by sampling the discharge current and high-voltage signals. However, the measuring accuracy of these methods is limited, and they are not convenient to use in practice. This paper presents a versatile, automated system for power measurement in an ac silent discharge. The system combines high-accuracy A/D data acquisition technology with the q-v trace method, Experimental results and analysis are presented to show the improved accuracy, speed of response, and convenience over conventional measuring methods. The method discussed here is applicable to the power measurement in similar discharges, such as ac corona discharges, etc.
引用
收藏
页码:563 / 570
页数:8
相关论文
共 18 条
[1]  
*ASTM, 1993, 1993 ANN BOOK ASTM S, pD3382
[2]  
*AWWA RES FDN, 1991, OZ WAT TREATM APPL E
[3]   A COMMENTARY ON PARTIAL DISCHARGE MEASUREMENT AND DETECTION [J].
BARTNIKAS, R .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (05) :629-652
[4]  
Kogelschatz U. U., 1995, HDB ELECTROSTATIC PR
[5]  
Manley T. C., 1943, T ELECTROCHEM SOC, V84, P83, DOI DOI 10.1149/1.3071556
[6]   CORONA CHARACTERISTICS OF CONDUCTOR BUNDLES UNDER IMPULSE VOLTAGES [J].
MARUVADA, PS ;
MENEMENLIS, H ;
MALEWSKI, R .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (01) :102-115
[7]   TRANSFORMER MAGNETIZING CURRENT AND IRON-CORE LOSSES IN HARMONIC POWER-FLOW [J].
MASOUM, MAS ;
FUCHS, EF .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) :10-18
[8]   A CERAMIC-BASED OZONIZER USING HIGH-FREQUENCY DISCHARGE [J].
MASUDA, S ;
AKUTSU, K ;
KURODA, M ;
AWATSU, Y ;
SHIBUYA, Y .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (02) :223-231
[9]  
MIZUNO A, 1990, IEEE IAS ANN M 1, P815
[10]  
MIZUNO A, 1994, IEEE IAS ANN M, V3, P1550