Gas sensing in microplates with optodes: Influence of oxygen exchange between sample, air, and plate material

被引:28
作者
Arain, S
Weiss, S
Heinzle, E
John, GT
Krause, C
Klimant, I
机构
[1] Graz Univ Technol, Inst Analyt Chem Micro & Radiochem, A-8010 Graz, Austria
[2] Univ Regensburg, Inst Analyt Chem Chem & Biosensors, D-8400 Regensburg, Germany
[3] Univ Saarland, Dept Biochem Engn, D-6600 Saarbrucken, Germany
[4] PreSens GmbH, Regensburg, Germany
关键词
optical oxygen sensor; oxygen transfer; optode; microplate sealing;
D O I
10.1002/bit.20348
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Microplates with integrated optical oxygen sensors are a new tool to study metabolic rates and enzyme activities. Precise measurements are possible only if oxygen exchange between the sample and the environment is known. In this study we quantify gas exchange in plastic microplates. Dissolved oxygen was detected using either an oxygen-sensitive film fixed at the bottom of each well or a needle-type sensor. The diffusion of oxygen into wells sealed with different foils, paraffin oil, and paraffin wax, respectively, was quantified. Although foil covers showed the lowest oxygen permeability, they include an inevitable gas phase between sample and sealing and are difficult to manage. The use of oil was found to be critical due to the extensive shaking caused by movement of the plates during measurements in microplate readers. Thus, paraffin wax was the choice material because it avoids convection of the sample and is easy to handle. Furthermore, without shaking, significant gradients in pO(2) levels within a single well of a polystyrene microplate covered with paraffin oil were detected with the needle-type sensor. Higher O-P(2) levels were obtained near the surface of the sample as well as near the wall of the well. A significant diffusion of oxygen through the plastic plate material was found using plates based on polystyrene. Thus, the location of a sensor element within the well has an effect on the measured O-P(2) level. Using a sensor film fixed on the bottom of a well or using a dissolved pO(2)-sensitive indicator results in pO(2) offset and in apparently lower respiration rates or enzyme activities. Oxygen diffusion through a polystyrene microplate was simulated for measurements without convection-that is, for samples without oxygen diffusion through the cover and for unshaken measurements using permeable sealings. This mathematical model allows for calculation of the correct kinetic parameters. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 22 条
[1]   PURIFICATION AND CHARACTERIZATION OF A PYRANOSE OXIDASE FROM THE BASIDIOMYCETE PENIOPHORA-GIGANTEA AND CHEMICAL-ANALYSES OF ITS REACTION-PRODUCTS [J].
DANNEEL, HJ ;
ROSSNER, E ;
ZEECK, A ;
GIFFHORN, F .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1993, 214 (03) :795-802
[2]  
DUNN IJ, 1992, BIOL REACTION ENG DY, P701
[3]   Comparative studies on algal toxicity testing using fluorometric microplate and Erlenmeyer flask growth-inhibition assays [J].
Eisentraeger, A ;
Dott, W ;
Klein, J ;
Hahn, S .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2003, 54 (03) :346-354
[4]   DIFFUSION OF OXYGEN INTO IRRADIATED POLYPROPYLENE FILMS [J].
EKEN, M ;
TURHAN, S ;
KAPTAN, Y ;
GUVEN, O .
RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6) :809-812
[5]  
GIBSON QH, 1964, J BIOL CHEM, V239, P3927
[6]   Fluorescence-based cell viability screening assays using water-soluble oxygen probes [J].
Hynes, J ;
Floyd, S ;
Soini, AE ;
O'Connor, R ;
Papkovsky, DB .
JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (03) :264-272
[7]  
INGHAM J, 2000, COMPUTER PROGRAM CD
[8]  
John GT, 2001, BIOTECHNOL BIOENG, V72, P620, DOI 10.1002/1097-0290(20010320)72:6<620::AID-BIT1027>3.0.CO
[9]  
2-W
[10]   Integrated optical sensing of dissolved oxygen in microtiter plates: A novel tool for microbial cultivation [J].
John, GT ;
Klimant, I ;
Wittmann, C ;
Heinzle, E .
BIOTECHNOLOGY AND BIOENGINEERING, 2003, 81 (07) :829-836