Prophylactic intramedullary femoral rodding during total knee arthroplasty with simultaneous femoral plate removal

被引:10
作者
Ries, MD [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
关键词
total knee arthroplasty; femur; fracture; plate; stress riser; supracondylar; femoral intramedullary rodding;
D O I
10.1016/S0883-5403(98)80019-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Removal of a plate from the distal femur creates a risk of fracture through the screw holes. This is a particular concern when a total knee arthroplasty is present because supracondylar fracture may occur with minimal trauma. A patient who presents after prior plating of a distal femur fracture with osteoporosis, retained hardware associated with pain, and gonarthrosis severe enough to warrant total knee arthroplasty is often difficult to manage. Prophylactic intramedullary redding is a well-accepted method of treating pathologic stress risers in the femur. An intramedullary rod can be inserted into the femur at the time of total knee arthroplasty. This method permits simultaneous plate removal and total knee arthroplasty while protecting the femur from postoperative fracture.
引用
收藏
页码:718 / 721