Feasibility of continuous multiorgan variability analysis in the intensive care unit

被引:12
作者
Bradley, Beverly [2 ]
Green, Geoffrey C. [2 ]
Batkin, Izmail [2 ]
Seely, Andrew J. E. [1 ,2 ,3 ]
机构
[1] Univ Ottawa, Div Thorac Surg, Ottawa, ON K1H 8L6, Canada
[2] Ottawa Hosp Res Inst, Ottawa, ON K1H 8L6, Canada
[3] Univ Ottawa, Dept Crit Care Med, Ottawa, ON K1H 8L6, Canada
基金
加拿大健康研究院;
关键词
Heart rate variability; Respiratory rate variability; Continuous waveform monitoring; Multiorgan; Data loss; Data quality; HEART-RATE-VARIABILITY; ORGAN DYSFUNCTION SYNDROME; PHYSIOLOGICAL DATA; BREATHING PATTERN; RESPIRATORY RATE; ACQUISITION; SYSTEM; TECHNOLOGY; COMPLEXITY; PREDICTOR;
D O I
10.1016/j.jcrc.2011.09.009
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Purpose: The aim of the study was to evaluate the feasibility of continuous heart and respiratory rate variability (HRV and RRV, respectively) monitoring in critically ill patients derived from electrocardiogram (ECG) and end-tidal capnography (etCO(2)) waveforms. Methods: Thirty-four patients (age, 56.5 +/- 15.9 years; Acute Physiology and Chronic Health Evaluation II score, 22.8 +/- 6.7) underwent continuous recording of ECG and etCO(2) waveforms from intensive care unit admission and intubation to discharge or maximum of 14 days. Overlapping 5-minute windows were analyzed with a wide range of variability measures (time, frequency, entropy, and scale-invariant and nonlinear domains). Waveform data quality, presence of disconnections and arrhythmias, quality of beat and breath detection, and subsequent variability computations were evaluated. Results: Patients were enrolled for 11.0 +/- 3.6 days. The proportion of missing waveform data among all patients was (median [interquartile range, maximum]) 2.9% (1.3%-9.7%, 36.4%) for ECG and 3.1% (1.1%-11.4%, 84.5%) for etCO(2). Heart rate variability data loss (ie, proportion of windows removed) was 1.3% (1.0%-2.1%, 5.9%) due to disconnection, 0.6% (0.1%-3.9%, 39.5%) due to atrial fibrillation, and 6.6% (1.4%-17.9%, 89.0%) due to data cleaning. Respiratory rate variability data loss was 7.3% (2.9%-11.6%, 47.7%) due to disconnection (or apnea) and 5.5% (2.9%-8.4%, 56.4%) due to cleaning. Continuous individualized multiorgan variability analysis processing resulted in HRV and RRV computations for 81.2% +/- 25.0% and 87.5% +/- 11.9% of available ECG and etCO(2) waveform data, respectively. Conclusions: The quality of continuously recorded ECG and etCO(2) waveforms in critically ill patients is adequate for subsequent continuous variability monitoring in this pilot study. The clinical utility of continuous variability analysis merits further investigation. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:218.e9 / 218.e20
页数:12
相关论文
共 29 条
[1]
Continuous Multi-Parameter Heart Rate Variability Analysis Heralds Onset of Sepsis in Adults [J].
Ahmad, Saif ;
Ramsay, Tim ;
Huebsch, Lothar ;
Flanagan, Sarah ;
McDiarmid, Sheryl ;
Batkin, Izmail ;
McIntyre, Lauralyn ;
Sundaresan, Sudhir R. ;
Maziak, Donna E. ;
Shamji, Farid M. ;
Hebert, Paul ;
Fergusson, Dean ;
Tinmouth, Alan ;
Seely, Andrew J. E. .
PLOS ONE, 2009, 4 (08)
[2]
Inappropriate sympathetic activation at onset of septic shock - A spectral analysis approach [J].
Annane, D ;
Trabold, F ;
Sharshar, T ;
Jarrin, I ;
Blanc, AS ;
Raphael, JC ;
Gajdos, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (02) :458-465
[3]
Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndrome [J].
Bien, MY ;
Hseu, SS ;
Yien, HW ;
Kuo, BIT ;
Lin, YT ;
Wang, JH ;
Kou, YR .
INTENSIVE CARE MEDICINE, 2004, 30 (02) :241-247
[4]
Buchman Timothy G, 2002, Curr Opin Crit Care, V8, P311, DOI 10.1097/00075198-200208000-00007
[5]
Unconstrained detection of respiration rhythm and pulse rate with one under-pillow sensor during sleep [J].
Chen, W ;
Zhu, X ;
Nemoto, T ;
Kanemitsu, Y ;
Kitamura, K ;
Yamakoshi, K .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) :306-312
[6]
Heart rate variabili measures as predictors of in-hospital mortality in ED patients with sepsis [J].
Chen, Wei-Lung ;
Chen, Jiann-Hwa ;
Huang, Chien-Cheng ;
Kuo, Cheng-Deng ;
Huang, Chun-I ;
Lee, Liang-Shong .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (04) :395-401
[7]
Comparison of Respiratory Rates Derived from Heart Rate Variability, ECG Amplitude, and Nasal/Oral Airflow [J].
Cysarz, Dirk ;
Zerm, Roland ;
Bettermann, Henrik ;
Fruehwirth, Matthias ;
Moser, Maximilian ;
Kroez, Matthias .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (12) :2085-2094
[8]
Pattern of spontaneous breathing: potential marker for weaning outcome - Spontaneous breathing pattern and weaning from mechanical ventilation [J].
El-Khatib, M ;
Jamaleddine, G ;
Soubra, R ;
Muallem, M .
INTENSIVE CARE MEDICINE, 2001, 27 (01) :52-58
[9]
Approximate entropy of respiratory rate and tidal volume during weaning from mechanical ventilation [J].
Engoren, M .
CRITICAL CARE MEDICINE, 1998, 26 (11) :1817-1823
[10]
PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220