Simultaneous determination of uric acid and creatinine in biological fluids by column-switching liquid chromatography with ultraviolet detection

被引:25
作者
Seki, T
Yamaji, K
Orita, Y
Moriguchi, S
Shinoda, A
机构
[1] OSAKA UNIV,SCH ALLIED HLTH SCI,FAC MED,TOYONAKA,OSAKA 560,JAPAN
[2] SHOWA DENKO CO LTD,SPECIALTY CHEM DIV,MINATO KU,TOKYO 105,JAPAN
关键词
column switching; uric acid; creatinine;
D O I
10.1016/0021-9673(95)01218-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A column-switching liquid chromatographic method for the simultaneous determination of uric acid and creatinine in human serum and urine was developed. Creatinine and uric acid were separated by size-exclusion chromatography on a hydrophilic gel column (C1) and creatinine eluted from C1 was separated from proteins by filtration through a longer hydrophilic gel column (C2). The creatinine fraction eluted from C2 was transferred to a weakly acidic cation-exchange column (C3) and then to a strongly acidic cation-exchange column (C4). Uric acid eluted from C1 after creatinine was transferred to an anion-exchange column (C5) and then to a hydrophilic gel column (C6). The mobile phase was a mixed buffer of pH 5.1 (propionic acid-succinic acid-NaOH, 60:15:60 mmol/l in water). Diluted serum and urine could be injected onto C1, and C1 was backflushed after the transfer of uric acid from C1 to C5. Creatinine and uric acid in the eluate were determined by measuring their ultraviolet absorption at 234 and 290 nm, respectively. The recovery of uric acid and creatinine added to diluted serum (20-fold dilution, concentration 20 and 5 mu mol/l, respectively) was 98.9 +/- 0.56% and 100.9 +/- 1.29%, respectively. The recovery of uric acid and creatinine added to diluted urine (100-fold dilution, concentration 50 and 100 mu mol/l, respectively) was 99.4 +/- 0.72% and 98.7 +/- 1.45%, respectively (mean +/- R.S.D., n=6).
引用
收藏
页码:139 / 145
页数:7
相关论文
共 24 条
[1]  
DULFFER T, 1986, Z ANAL CHEM, V324, P333
[2]  
ETOH T, 1992, J LIQ CHROMATOGR, V15, P1656
[3]  
GINMAN RFA, 1985, CLIN CHEM, V31, P331
[4]  
HARMOINEN A, 1991, CLIN CHEM, V37, P563
[5]  
KAGDAL B, 1990, J CHROMATOGR, V527, P21
[6]   NEW ANALYZER FOR THE DETERMINATION OF URINARY VANILLYLMANDELIC ACID, HOMOVANILLIC-ACID AND CREATININE [J].
KAWAGUCHI, S ;
HIRACHI, N ;
FUKAMACHI, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 567 (01) :11-19
[7]  
KOJIMA T, 1986, CLIN CHEM, V32, P287
[8]   DETERMINATION OF URIC-ACID IN BIOLOGICAL-FLUIDS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
MILNER, JA ;
PERKINS, EG .
ANALYTICAL BIOCHEMISTRY, 1978, 88 (02) :560-565
[9]   HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF UREA, CREATININE, AND URIC-ACID IN SERUM AND URINE [J].
MULLER, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (05) :464-467
[10]   SIMULTANEOUS DETERMINATION OF CREATINE AND CREATININE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MURAKITA, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (02) :471-473