Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms

被引:59
作者
Kashani, Rojano [1 ]
Hub, Martina [1 ]
Kessler, Marc L. [1 ]
Balter, James M. [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
deformable alignment; IGRT; image registration;
D O I
10.1118/1.2739812
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat "diaphragm" to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using this method. Repeat measurement of marker positions showed an accuracy of better than 1 mm in identification of the reference marks. Testing the method on several image registration algorithms showed that the system is capable of evaluating errors quantitatively. This phantom is able to quantitatively assess the accuracy of deformable image registration, using a measure of accuracy that is independent of the signals that drive the deformation parameters. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:2785 / 2788
页数:4
相关论文
共 19 条
[1]
Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[2]
CHOU YY, 2004, IEEE INT S BIOMED IM, V1, P716
[3]
Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines [J].
Coselmon, MM ;
Balter, JM ;
McShan, DL ;
Kessler, ML .
MEDICAL PHYSICS, 2004, 31 (11) :2942-2948
[4]
Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain [J].
Fitzpatrick, JM ;
Hill, DLG ;
Shyr, Y ;
West, J ;
Studholme, C ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) :571-585
[5]
Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method [J].
Guerrero, T ;
Zhang, G ;
Huang, TC ;
Lin, KP .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) :4147-4161
[6]
Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer [J].
Hansen, EK ;
Bucci, MK ;
Quivey, JM ;
Weinberg, V ;
Xia, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :355-362
[7]
Technical note: A deformable phantom for dynamic modeling in radiation therapy [J].
Kashani, Rojano ;
Lam, Kwok ;
Litzenberg, Dale ;
Balter, James .
MEDICAL PHYSICS, 2007, 34 (01) :199-201
[8]
Image registration and data fusion in radiation therapy [J].
Kessler, M. L. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 :S99-S108
[9]
Synchronized dynamic dose reconstruction [J].
Litzenberg, Dale W. ;
Hadley, Scott W. ;
Tyagi, Neelarn ;
Baiter, James M. ;
Ten Haken, Randall K. ;
Chetty, Indrin J. .
MEDICAL PHYSICS, 2007, 34 (01) :91-102
[10]
An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy [J].
Malsch, U. ;
Thieke, C. ;
Huber, P. E. ;
Bendl, R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) :4789-4806