Mid-infrared spectroscopy coupled to sequential injection analysis for the on-line monitoring of the acetone-butanol fermentation process

被引:48
作者
Kansiz, M
Gapes, JR
McNaughton, D
Lendl, B
Schuster, KC
机构
[1] Vienna Univ Technol, Inst Analyt Chem, A-1060 Vienna, Austria
[2] Vienna Univ Technol, Inst Chem Engn Fuel & Environm Technol, A-1060 Vienna, Austria
[3] Monash Univ, Dept Chem, Melbourne, Vic 3168, Australia
关键词
on-line; bioprocess monitoring; mid-infrared spectroscopy; attenuated total reflection; glucose; butanol; butyrate;
D O I
10.1016/S0003-2670(01)00919-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FTIR) spectroscopy, coupled to sequential injection analysis (SIA) was employed fur the on-line monitoring of an acetone-butanol fermentation by simultaneously determining acetone, acetate, ra-butanol, butyrate and glucose from the mid-IR spectra of the samples. The analysis system (SIA-FTIR) developed was completely computer controlled, requiring only minute amounts of NaOH and Na2CO3 as reagents and was capable of performing 30 analyte determinations per hour From a batch fermentation run of 55 h duration, samples were automatically drawn and analysed at 14 different points of time. The analysis by SIA-FTIR comprised of triplicate injections, from each of which two spectra one with 4 cm(-1) the other with 8 cm(-1) spectral resolution were obtained. In addition, triplicate reference analysis by gas chromatography and enzymatic test kits were also done at corresponding points of time. Based on the data of the reference analysis a partial least squares (PLS) model was established and validated by a leave-one-out cross validation. Best results were obtained using the second derivatised spectra collected at 8 cm(-1) resolution. The regression coefficients and standard errors of prediction (S.E.P.) were as follows: acetone, r = 0.999, S.E.P. = 0.077 g/l; acetate, r = 0.998, S.E.P. = 0.063 g/l; butyrate, r = 0.955 and S.E.P. = 0.058 g/l; il-butanol, r = 0.999, S.E.P. = 0.301 g/l and glucose, r = 0.999, S.E.P. = 0.493 g/l. The high quality of the results obtained, and the observation that the precision of the SIA-FTIR analysis was as good and often better than those of the reference methods, showed that SIA-FTIR is a powerful tool for rapid on-line bioprocess monitoring. (C) 2001 Elsevier Science B.V. All, rights reserved.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 30 条
[1]  
ARNOLD SA, 2000, P ESBES 3 3 EUR S BI
[2]  
BERETON RG, 1993, APPL MATH STAT LAB S
[3]  
CANNIZZARO C, 2000, P ESBES 3 3 EUR S BI
[4]  
Chauvatcharin S, 1998, BIOTECHNOL BIOENG, V58, P561, DOI 10.1002/(SICI)1097-0290(19980620)58:6<561::AID-BIT1>3.0.CO
[5]  
2-G
[6]  
COMBERBACH DM, 1985, ENZYME MICROB TECH, V7, P543
[7]   In situ monitoring of an Escherichia coli fermentation using a diamond composition ATR probe and mid-infrared spectroscopy [J].
Doak, DL ;
Phillips, JA .
BIOTECHNOLOGY PROGRESS, 1999, 15 (03) :529-539
[8]   PROCESS ANALYSIS OF THE ACETONE-BUTANOL FERMENTATION BY QUADRUPOLE MASS-SPECTROMETRY [J].
DOERNER, P ;
LEHMANN, J ;
PIEHL, H ;
MEGNET, R .
BIOTECHNOLOGY LETTERS, 1982, 4 (09) :557-562
[9]   New insights and novel developments in clostridial acetone/butanol/isopropanol fermentation [J].
Dürre, P .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1998, 49 (06) :639-648
[10]   Monitoring of fermentation processes producing lactic acid bacteria by mid-infrared spectroscopy [J].
Fayolle, P ;
Picque, D ;
Corrieu, G .
VIBRATIONAL SPECTROSCOPY, 1997, 14 (02) :247-252