Diagnostic value of technetium-99m methoxyisobutyl isonitrile (99mTc-MIBI) scintigraphy in detecting thyroid cancer metastases:: A critical evaluation

被引:31
作者
Alam, MS [1 ]
Kasagi, K [1 ]
Misaki, T [1 ]
Miyamoto, S [1 ]
Iwata, M [1 ]
Iida, Y [1 ]
Konishi, J [1 ]
机构
[1] Kyoto Univ, Dept Nucl Engn, Sakyo Ku, Kyoto 606, Japan
关键词
D O I
10.1089/thy.1998.8.1091
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Technetium-99m methoxyisobutyl isonitrile (Tc-99m-MIBI) scintigraphy has recently been used in clinical application for detecting thyroid cancer metastases, its role being considered supplementary to serum thyroglobulin (Tg) measurements and radioactive iodine (I-131) whole-body scans (WBS). The present retrospective study was designed to elucidate the role of Tc-99m-MIBZ scans in localizing metastatic lesions by assessing sensitivity and specificity of the scan results obtained in a group of 68 thyroidectomized thyroid cancer patients. Presence or absence of thyroid cancer was judged with other diagnostic modes including serum Tg measurements, 131I WBS, bone scans, chest x-rays, computed tomography (CT), ultrasonography, histopathology, and evolution of disease during follow-up. All scans were read on lesion basis for detecting neck, lung, and bone metastases and also on region basis, namely head-neck, chest, and abdomen-pelvis-extremities (ab-p-ex) areas. The sensitivity of detection was 94.4% (17/18) for neck, 78.4% (40/51) for lung, and 92.8% (64/69) for skeletal lesions. Positive predictive value (PPV) and negative predictive value (NPV) were 96.3% (26/27) and 97.7% (43/44) for head-neck; 94.7% (71/75) and 50.0% (12/24) for chest; 100.0% (25/25) and 93.1% (54/58) for ab-p-ex regions, respectively. For all scan sites taken together, PPV and NPV were 96.1% (122/127) and 86.5% (109/126), respectively. In conclusion, the present study reveals that Tc-99m-MIBI can be proposed as a first-line diagnostic agent for the follow-up protocol of thyroid cancer patients, although the ability to detect small lung metastases is somewhat limited.
引用
收藏
页码:1091 / 1100
页数:10
相关论文
共 20 条
[1]
CLINICAL-EXPERIENCE WITH TC-99M MIBI IMAGING IN PATIENTS WITH MALIGNANT-TUMORS - PRELIMINARY-RESULTS AND COMPARISON WITH TL-201 [J].
AKTOLUN, C ;
BAYHAN, H ;
KIR, M .
CLINICAL NUCLEAR MEDICINE, 1992, 17 (03) :171-176
[2]
Value of combined technetium-99m hydroxy methylene diphosphonate and thallium-201 imaging in detecting bone metastases from thyroid carcinoma [J].
Alam, MS ;
Takeuchi, R ;
Kasagi, K ;
Misaki, T ;
Miyamoto, S ;
Iida, Y ;
Hidaka, A ;
Konishi, J .
THYROID, 1997, 7 (05) :705-712
[3]
BRIELE B, 1991, NUKLEARMED, V30, P115
[4]
CANER B, 1992, J NUCL MED, V33, P319
[5]
CLINICAL UTILITY OF TC-99M METHOXISOBUTYLISONITRILE IMAGING IN DIFFERENTIATED THYROID-CARCINOMA - COMPARISON WITH THALLIUM-2O1 AND I-131 NA SCINTIGRAPHY, AND SERUM THYROGLOBULIN QUANTITATION [J].
DADPARVAR, S ;
CHEVRES, A ;
TULCHINSKY, M ;
KRISHNABADRINATH, L ;
KHAN, AS ;
SLIZOFSKI, WJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (11) :1330-1338
[6]
Feine U, 1996, J NUCL MED, V37, P1468
[7]
FOLDES I, 1993, EUR J NUCL MED, V20, P330
[8]
HALUK H, 1991, J NUCL MED, V32, P1700
[9]
UPTAKE AND KINETICS OF TC-99M HEXAKIS 2-METHOXY ISOBUTYL ISONITRILE IN BENIGN AND MALIGNANT LESIONS IN THE LUNGS [J].
HASSAN, IM ;
SAHWEIL, A ;
CONSTANTINIDES, C ;
MAHMOUD, A ;
NAIR, M ;
OMAR, YT ;
ABDELDAYEM, HM .
CLINICAL NUCLEAR MEDICINE, 1989, 14 (05) :333-340
[10]
DETECTION OF NASOPHARYNGEAL CARCINOMA USING TC-99(M) METHOXYISOBUTYLISONITRILE SPECT [J].
KAO, CH ;
WANG, SJ ;
LIN, WY ;
HSU, CY ;
LIAO, SQ ;
YEH, SH .
NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (01) :41-46