A new flow cell design for chemiluminiscence analysis

被引:21
作者
Campíns-Falcó, P [1 ]
Tortajada-Genaro, LA [1 ]
Bosch-Reig, F [1 ]
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Burjassot, Spain
关键词
chemiluminescence; chromium determination; cell design; luminol-hydrogen peroxide reaction;
D O I
10.1016/S0039-9140(01)00445-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study proposes a new flow cell called a bundle cell for chemiluminescence analysis. The results obtained were compared with those achieved by manual and automated batch procedures and flow manifolds with different cells: an common quartz flow cell, a helix cell and the most used spiral cell. Figures of merit such as limit of detection, sensitivity, accuracy and precision for the Cr(III) determination were established with light emission produced by catalysed Cr(III) luminol oxidation by hydrogen peroxide in a basic aqueous solution. An improvement in sensitivity about 50% as compared with the spiral cell and even larger with respect to the other flow cells tested was observed. The limit of detection provided was lower than those obtained with the other flow cells. In reference to the batch mode, similar results were obtained with the bundle flow cell. Good results were obtained for several real water samples containing chromium at different concentrations. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:403 / 413
页数:11
相关论文
共 15 条
[1]  
CELA R, 1984, QUIM ANAL, V3, P87
[2]   HALIDE ION ENHANCEMENT OF CHROMIUM(III), IRON(II), AND COBALT(II) CATALYSIS OF LUMINOL CHEMI-LUMINESCENCE [J].
CHANG, CA ;
PATTERSON, HH .
ANALYTICAL CHEMISTRY, 1980, 52 (04) :653-656
[3]   DETERMINATION OF AQUEOUS OZONE FOR POTABLE WATER-TREATMENT APPLICATIONS BY CHEMILUMINESCENCE FLOW-INJECTION ANALYSIS - A FEASIBILITY STUDY [J].
CHUNG, HK ;
BELLAMY, HS ;
DASGUPTA, PK .
TALANTA, 1992, 39 (06) :593-598
[4]   LOW-DISPERSION CHEMILUMINESCENCE DETECTION FOR PACKED CAPILLARY LIQUID-CHROMATOGRAPHY [J].
DEJONG, GJ ;
LAMMERS, N ;
SPRUIT, FJ ;
DEWAELE, C ;
VERZELE, M .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1458-1461
[5]   FLOW-INJECTION CHEMILUMINESCENCE METHOD FOR THE SELECTIVE DETERMINATION OF CHROMIUM(III) [J].
ESCOBAR, R ;
LIN, QX ;
GUIRAUM, A ;
DELAROSA, FF .
ANALYST, 1993, 118 (06) :643-647
[6]  
ESCOBAR R, 1996, INT J ENVIRON AN CH, V61, P169
[7]  
Greenberg A. E., 1992, STANDARD METHODS EXA
[8]   RAPID CHEMI-LUMINESCENCE MEASUREMENTS BY DIGITAL PROCESSING OF SIGNALS AND SMOOTHING BY FOURIER-TRANSFORM [J].
HAYASHI, Y ;
IKEDA, M ;
YUKI, H .
ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) :81-88
[9]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[10]   DETERMINATION OF TRACE AMOUNTS OF CHROMIUM(III) USING CHEMILUMINESCENCE ANALYSIS [J].
SEITZ, WR ;
SUYDAM, WW ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1972, 44 (06) :957-&