Optimizing accuracy in magnetic resonance imaging-guided stereotaxis: a technique with validation based on the anterior commissure-posterior commissure line

被引:33
作者
diPierro, CG
Francel, PC
Jackson, TR
Kamiryo, T
Laws, ER
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Neurosurg, Charlottesville, VA 22908 USA
[2] NYU, Dept Neurosurg, New York, NY 10016 USA
[3] Univ Oklahoma, Dept Neurosurg, Oklahoma City, OK USA
关键词
stereotaxis; stereotactic localization; pallidotomy; thalamotomy; Parkinson's disease; movement disorder;
D O I
10.3171/jns.1999.90.1.0094
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Some of the earliest successful frame-based stereotactic interventions directed toward the thalamus and basal ganglia depended on identifying the anterior commissure (AC) and posterior commissure (PC) in a sagittal ventriculogram and defining the intercommissural line that connects them in the midsagittal plane. The AC-PC line became the essential landmark for the localization of neuroanatomical targets in the basal ganglia and diencephalon and for relating them to stereotactic atlases. Stereotactic/functional neurosurgery has come to rely increasingly on magnetic resonance (MR) imaging guidance, and methods for accurately determining the AC-PC line on MR imaging are being developed. The goal of the present article is to present the authors' technique. Methods. The technique described uses MR sequences that minimize geometric distortion and registration error, thereby maximizing accuracy in AC-PC line determinations from axially displayed MR data. The technique is based on the authors' experience with the Leksell G-frame but can be generalized to other MR imaging-based stereotactic systems. This methodology has been used in a series of 62 stereotactic procedures in 47 adults (55 pallidotomies and seven thalamotomies) with preliminary results that compare favorably with results reported when using microelectrode recordings. The measurements of the AC-PC line reported here also compare favorably with those based on ventriculography and computerized tomography scanning. Conclusions. The methodology reported here is critical in maintaining the accuracy and utility of MR imaging as its role in modern stereotaxy expands. Accurate parameters such as these aid in ensuring the safety, efficacy, and reproducibility of MR-guided stereotactic procedures.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 59 条
[1]   STEREOTAXIC VENTROLATERAL THALAMOTOMY - IS VENTRICULOGRAPHY NECESSARY [J].
ALTERMAN, RL ;
KALL, BA ;
COHEN, H ;
KELLY, PJ .
NEUROSURGERY, 1995, 37 (04) :717-721
[2]   SUBTHALAMOTOMY IN TREATMENT OF PARKINSONIAN TREMOR [J].
ANDY, OJ ;
SIAS, FR ;
JURKO, MF .
JOURNAL OF NEUROSURGERY, 1963, 20 (10) :860-&
[3]  
[Anonymous], NEUROSURGICAL ALLEVI
[4]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[5]  
BAKAY RAE, 1992, J NEUROSURG, V77, P487
[6]  
BERTRAND C, 1962, CONFIN NEUROL, V22, P274
[7]   ANATOMIC BASIS OF SURGICAL TREATMENT OF PARKINSONS DISEASE [J].
CARMAN, JB .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 279 (17) :919-+
[8]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[9]   TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING [J].
CHO, ZH ;
KIM, DJ ;
KIM, YK .
MEDICAL PHYSICS, 1988, 15 (01) :7-11
[10]   EFFECTS OF COREGISTRATION OF MR TO CT IMAGES ON MR STEREOTAXIC ACCURACY [J].
COHEN, DS ;
LUSTGARTEN, JH ;
MILLER, E ;
KHANDJI, AG ;
GOODMAN, RR .
JOURNAL OF NEUROSURGERY, 1995, 82 (05) :772-779