Flux enhancement during Dean vortex tubular membrane nanofiltration: 13. Effects of concentration and solute type

被引:32
作者
Mallubhotla, H [1 ]
Schmidt, M [1 ]
Lee, KH [1 ]
Belfort, G [1 ]
机构
[1] Rensselaer Polytech Inst, Isermann Dept Chem Engn, Troy, NY 12180 USA
基金
美国国家科学基金会;
关键词
dean vortices; nanofiltration; concentration; inorganic salts; amino acids;
D O I
10.1016/S0376-7388(98)00255-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Controlled centrifugal instabilities (called Dean vortices) resulting from sufficient flow in composite polyamide-poly(ether sulfone) helical membrane tubes have been used to reduce concentration polarization during nanofiltration. These vortices enhance back-migration through convective flow away from the membrane-solution interface and increased shear at the membrane-solution interface and allow for increased membrane permeation rates. As a result, solute concentrations at the membrane-solution interface and resulting osmotic-driven back flow are reduced. The performance of two sets of modules (designated Set II and Set III), each set containing a prototype vortex generating helical tubular nanofiltration (NF) element and a conventional linear element was evaluated. Nanofiltration of aqueous solutions of inorganic salts (including KCI, K2SO4 and K3PO4) and amino acids of similar molecular weight (including glutamic acid, glutamine and lysine) was performed with Set II. These experiments, designed to evaluate the effects of solute type, were conducted at the same energy consumption and transmembrane pressures. Both membrane swelling and charge effects were evident as a function of varying the pH during membrane filtration of both inorganic salts and aminoacids. Both flux and rejection were higher for the helical module than the linear module during amino acid nanofiltration. A new modified phenomenological model was shown to be effective for predictive purposes for cases of responsive concentration polarization. Its applicability is validated by performing nanofiltration of aqueous MgSO4 solutions with a new set of modules designated as Set In. Modules of Set III contained dissimilar helical and linear elements. The model was then tested against the results obtained previously. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 27 条
[1]   DIAGNOSIS OF MEMBRANE FOULING USING A ROTATING ANNULAR FILTER .2. DILUTE PARTICLE SUSPENSIONS OF KNOWN PARTICLE-SIZE [J].
BELFORT, G ;
MIKULASEK, P ;
PIMBLEY, JM ;
CHUNG, KY .
JOURNAL OF MEMBRANE SCIENCE, 1993, 77 (01) :23-39
[2]   DIAGNOSIS OF MEMBRANE FOULING USING A ROTATING ANNULAR FILTER .1. CELL-CULTURE MEDIA [J].
BELFORT, G ;
PIMBLEY, JM ;
GREINER, A ;
CHUNG, KY .
JOURNAL OF MEMBRANE SCIENCE, 1993, 77 (01) :1-22
[3]   FLUID-MECHANICS IN MEMBRANE FILTRATION - RECENT DEVELOPMENTS [J].
BELFORT, G .
JOURNAL OF MEMBRANE SCIENCE, 1989, 40 (02) :123-147
[4]  
Belfort G., 1993, US Patent, Patent No. [5,204,002, 5204002]
[5]  
BLAIS P, 1977, REVERSE OSMOSIS SYNT
[6]   DEAN VORTICES WITH WALL FLUX IN A CURVED CHANNEL MEMBRANE SYSTEM .1. A NEW APPROACH TO MEMBRANE MODULE DESIGN [J].
BREWSTER, ME ;
CHUNG, KY ;
BELFORT, G .
JOURNAL OF MEMBRANE SCIENCE, 1993, 81 (1-2) :127-137
[7]   DEAN VORTICES IN CURVED TUBE FLOW .5. 3-D MRI AND NUMERICAL-ANALYSIS OF THE VELOCITY-FIELD [J].
CHUNG, KY ;
BELFORT, G ;
EDELSTEIN, WA ;
LI, XM .
AICHE JOURNAL, 1993, 39 (10) :1592-1602
[8]  
CHUNG KY, 1993, J MEMBRANE SCI, V81, P151
[9]  
CHUNG KY, 1993, J MEMBRANE SCI, V81, P139
[10]   Dean vortices with wall flux in a carved channel membrane system .2. The velocity field [J].
Chung, KY ;
Brewster, ME ;
Belfort, G .