On-site calibration method based on stepwise solid-phase microextraction

被引:26
作者
Xiong, GH [1 ]
Chen, Y [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Fac Sci, Waterloo, ON N2L 3G1, Canada
关键词
calibration; stepwise solid-phase microextraction; solid-phase microextraction; field extraction methods; benzene; toluene; ethylbenzene; xylenes; tetrachloroethylene;
D O I
10.1016/S0021-9673(03)00602-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A stepwise solid-phase microextraction (SPME) method was developed for on-site calibration of SPME for volatile organic compounds analysis. In this approach, a 75-mum Carboxen-polydimethylsiloxane coated fibre was loaded with a standard prior to exposure to samples of interest. Extraction time for the target analytes can be controlled independently from that of the standard, and the response factors for the target analytes can be adjusted accordingly. A good reproducibility of the response factors for BTEXs (benzene, toluene, ethylbenzene and xylenes) was obtained with stepwise SPME. Satisfactory results were obtained by using this method for quantitative analysis of BTEXs in the air of a gas station when tetrachloroethylene was used as a standard. The introduction of standard via the stepwise SPME procedure makes SPME more useful in field applications. It can be used to detect leaks, contaminations and losses from loading of a standard onto a fibre to introduction of the fibre to an analytical instrument. However, this method cannot be used for compensation of sample matrix effects. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 11 条
[2]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[3]   Calibration in chemical measurement processes:: I.: A metrological approach [J].
Cuadros-Rodríguez, L ;
Gámiz-Cracia, L ;
Almansa-López, E ;
Laso-Sánchez, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (04) :195-206
[4]  
HARRIS DC, 1999, QUANTITATIVE CHEM AN
[5]   Field air analysis with SPME device [J].
Koziel, J ;
Jia, MY ;
Khaled, A ;
Noah, J ;
Pawliszyn, J .
ANALYTICA CHIMICA ACTA, 1999, 400 :153-162
[6]   Optimization of the SPME device design for field applications [J].
Müller, L ;
Górecki, T ;
Pawliszyn, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (07) :610-616
[7]  
Pawliszyn J., 1999, APPL SOLID PHASE MIC
[8]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[9]   Vertical and horizontal variability of volatile organic compounds in homes in Eastern Germany [J].
Schneider, P ;
Lörinci, G ;
Gebefügi, IL ;
Heinrich, J ;
Kettrup, A ;
Wichmann, HE .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1999, 9 (04) :282-292
[10]  
SHIREY R, 1998, AM ENV LAB, V12, P21