Cytotoxic effects exerted by polyarylsulfone dialyser membranes depend on different sterilization processes

被引:13
作者
El Golli-Bennour, Emna [1 ]
Kouidhi, Bochra [1 ]
Dey, Mouna [1 ,2 ]
Younes, Rabia [1 ,2 ]
Bouaziz, Chayma [1 ]
Zaied, Chiraz [1 ]
Bacha, Hassen [1 ]
Achour, Addellatif [1 ,2 ]
机构
[1] Fac Med Dent, LRSBC, Monastir, Tunisia
[2] CHU Sahloul, Serv Nephrol Hemodialyse & Transplantat Renale, Sousse, Tunisia
关键词
Polyarylsulfone group; Dialyser membranes; Sterilization process; Cell viability; Oxidative stress; CHRONIC-RENAL-FAILURE; DIALYSIS PATIENTS; OXIDATIVE STRESS; HEMODIALYSIS-PATIENTS; CELLOPHANE MEMBRANES; GAMMA-RADIATION; BIOCOMPATIBILITY; PARAMETERS; POLYURETHANE; ANTIOXIDANTS;
D O I
10.1007/s11255-009-9653-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
100201 [内科学]; 100221 [泌尿外科学];
摘要
Polyarylsulfone group is one of the most important polymeric materials used in the biomedical field, due to its excellent properties, such as good thermal, chemical, and mechanical stability. There are three important polyarylsulfone polymers, all of which have excellent electrical properties: polysulfone (PSu), polyarylsulfone (PAS) and polyarylethersulfone (PAES). All these polymers have excellent creep, radiation and high temperature resistance. In this study, we aimed to determine the effect of three sterilization processes (steam, ethylene oxide and gamma rays) on cytotoxicity of polyarylsulfone dialysis membranes. Ten long-term dialysis patients and ten age-matched healthy controls were enrolled in our study. We analysed (1) serum effect on cultured endothelial cell viability using MTT assay and (2) lipid peroxidation assessed by serum malondialdehyde (MDA) formation at the beginning (T0), the middle (T2) and the end (T4) of haemodialysis (HD) session. Our results clearly showed that steam-sterilized membranes improve endothelial cell viability when compared to ethylene oxide or gamma rays-sterilized ones. Moreover, there is a increased generation of MDA in patients sera during HD session. The serum MDA concentration was about 3, 6 and 10 times higher, respectively, for steam, ethylene oxide and gamma rays sterilization procedures when compared to the MDA amount in healthy subject sera. We concluded that using steam instead of ethylene oxide or gamma rays for sterilization may improve the biocompatibility of polyarylsulfone membranes.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 39 条
[1]
AMORE A, 1995, J AM SOC NEPHROL, V6, P1278
[2]
Is steam sterilization really making any difference in dialysis-induced cytokine release? [J].
Aucella, F ;
Tetta, C ;
Tessore, V ;
De Nitti, C ;
Vigilante, M ;
Gatta, G ;
Grandone, E ;
Margaglione, M ;
Colaizzo, D ;
Cappucci, G ;
Modoni, S ;
Stallone, C .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (09) :832-837
[3]
Reduction of mononuclear cytokine production in hemodialysis patients treated with steam-sterilized low-flux polysulphone membranes [J].
Aucella, F ;
Vigilante, M ;
Grandone, E ;
Colaizzo, D ;
Margaglione, M ;
Modoni, S ;
Orlandini, G ;
Stallone, C .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (04) :210-215
[4]
Characterization of polyethersulfone hemodialysis membrane by ultrafiltration and atomic force microscopy [J].
Barzin, J ;
Feng, C ;
Khulbe, KC ;
Matsuura, T ;
Madaeni, SS ;
Mirzadeh, H .
JOURNAL OF MEMBRANE SCIENCE, 2004, 237 (1-2) :77-85
[5]
Becker BN, 1997, J AM SOC NEPHROL, V8, P475
[6]
Selection of a polyurethane membrane for the manufacture of ventricles for a totally implantable artificial heart:: Blood compatibility and biocompatibility studies [J].
Bélanger, MC ;
Marois, Y ;
Roy, R ;
Mehri, Y ;
Wagner, E ;
Zhang, Z ;
King, MW ;
Yang, MJ ;
Hahn, C ;
Guidoin, R .
ARTIFICIAL ORGANS, 2000, 24 (11) :879-888
[7]
Serum levels of soluble adhesion molecules in chronic renal failure and dialysis patients [J].
Bonomini, M ;
Reale, M ;
Santarelli, P ;
Stuard, S ;
Settefrati, N ;
Albertazzi, A .
NEPHRON, 1998, 79 (04) :399-407
[8]
The Effects of Kidney-Disease-Related Loss on Long-Term Dialysis Patients' Depression and Quality of Life: Positive Affect as a Mediator [J].
Chan, Ramony ;
Brooks, Robert ;
Erlich, Jonathan ;
Chow, Josephine ;
Suranyi, Michael .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (01) :160-167
[9]
HEMODIALYSIS LEUKOPENIA - PULMONARY VASCULAR LEUKOSTASIS RESULTING FROM COMPLEMENT ACTIVATION BY DIALYZER CELLOPHANE MEMBRANES [J].
CRADDOCK, PR ;
FEHR, J ;
DALMASSO, AP ;
BRIGHAM, KL ;
JACOB, HS .
JOURNAL OF CLINICAL INVESTIGATION, 1977, 59 (05) :879-888
[10]
Oxidative stress and δ-ALA-D activity in chronic renal failure patients [J].
da Silva, Adriane C. ;
Rocha, Joao B. T. ;
Morsch, Andre L. B. ;
Zanin, Rafael E. ;
Kaizer, Rosilene ;
Maldonado, Paula Acosta ;
Arantes, Luis C. ;
Silva, Luis A. ;
Morsch, Vera M. ;
Schetinger, Maria R. C. .
BIOMEDICINE & PHARMACOTHERAPY, 2007, 61 (2-3) :180-185