In vivo three-dimensional knee kinematics using a biplanar image-matching technique

被引:195
作者
Asano, T [1 ]
Akagi, M [1 ]
Tanaka, K [1 ]
Tamura, J [1 ]
Nakamura, T [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, Sakyo Ku, Kyoto 6068570, Japan
关键词
D O I
10.1097/00003086-200107000-00023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A biplanar image-matching technique was developed and applied to a study of normal knee kinematics in vivo under weightbearing conditions, Three-dimensional knee models of six volunteers were constructed using computed tomography, Projection images of the models were fitted onto anteroposterior and lateral radiographs of the knees at hyperextension and every 15 degrees from 0 degrees to 120 degrees flexion. Knee motion was reconstructed on the computer, The femur showed a medial pivoting motion relative to the tibia during knee flexion, and the average range of external rotation associated with flexion was 29.1 degrees. The center of the medial femoral condyle translated 3.8 mm anteriorly, whereas the center of the lateral femoral condyle translated 17.8 mm posteriorly, This rotational motion, with a medially offset center, could be interpreted as a screw home motion of the knee around the tibial knee axis and a posterior femoral rollback in the sagittal plane. However, the motion of the contact point differed from that of the center of the femoral condyle when the knee flexion angle was less than 30 degrees. Within this range, medial and lateral contact points translated posteriorly, and a posterior femoral rollback occurred, This biplanar image-matching technique is useful for investigating knee kinematics in vivo.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 30 条
[1]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[2]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]
Churchill DL, 1998, CLIN ORTHOP RELAT R, P111
[4]
CHURCHILL DL, 1996, T ORTHOP RES SOC, V42, P717
[5]
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[6]
Dennis DA, 1996, CLIN ORTHOP RELAT R, P107
[7]
INTERACTION BETWEEN INTRINSIC KNEE MECHANICS AND THE KNEE EXTENSOR MECHANISM [J].
DRAGANICH, LF ;
ANDRIACCHI, TP ;
ANDERSSON, GBJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (04) :539-547
[8]
A CORRELATIVE STUDY OF THE GEOMETRY AND ANATOMY OF THE DISTAL FEMUR [J].
ELIAS, SG ;
FREEMAN, MAR ;
GOKCAY, EI .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) :98-103
[9]
MOTION OF THE KNEE AFTER CONDYLAR RESURFACING - AN INVIVO STUDY [J].
ELNAHASS, B ;
MADSON, MM ;
WALKER, PS .
JOURNAL OF BIOMECHANICS, 1991, 24 (12) :1107-1117
[10]
BIOMECHANICS OF INTERNAL DERANGEMENT OF KNEE - PATHOMECHANICS AS DETERMINED BY ANALYSIS OF INSTANT CENTERS OF MOTION [J].
FRANKEL, VH ;
BURSTEIN, AH ;
BROOKS, DB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (05) :945-&