Magnetic sector ICPMS with desolvating micronebulization: Interference-free subpicogram determination of rare earth elements in natural samples

被引:53
作者
Field, MP [1 ]
Sherrell, RM [1 ]
机构
[1] Rutgers State Univ, Inst Marine & Coastal Sci, New Brunswick, NJ 08901 USA
关键词
D O I
10.1021/ac980455v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method has been developed combining desolvating micronebulization with magnetic sector inductively coupled plasma mass spectrometry (ICPMS) for the analysis of all 14 stable rare earth elements (REEs) in small samples of marine particulate matter. Application is demonstrated for REEs in suspended particles from a deep ocean hydrothermal vent plume and a geological reference material. A 100-fold reduction in oxide formation, relative to standard nebulizer-spray chamber sample introduction, makes oxide interference correction negligible, even for samples that are very enriched in Ba and light REEs, Enriched isotopes for one light and one heavy REE (Nd-145 and Yb-171) are used as both isotope dilution and internal standards, providing determination of all the REEs in one analysis. This standardization scheme eliminates the need for multimass drift correction used previously to achieve acceptable accuracy with external standardization techniques. Instead, the method exploits capabilities for accurate and precise determination of isotope ratios, a principal strength of ICPMS, and the mass-independent sensitivity of electric field scans on our double-focusing instrument. We demonstrate overall precision of less than or equal to 2% (1 sigma) and accuracy better than 6% for all the REEs (except Er = 8.7%), based on comparison to recommended values for USGS certified reference material BHVO-1 (basalt), This performance is similar to that obtained by full isotope dilution mass spectrometric techniques, but the new method is far simpler, requires 5 min sample(-1), and avoids interferences introduced by complex mixtures of enriched isotopes. Sensitivity of (1.2-1.4) x 10(6) counts s(-1) ppb(-1) and background intensities of 2-60 counts s(-1) provide excellent detection limits of 1-40 ppq, a 100-fold improvement on established ICPMS methods. The low sample introduction rate (100 mu L min(-1)) allows unprecedented absolute detection limits of 1-20 fg.
引用
收藏
页码:4480 / 4486
页数:7
相关论文
共 30 条
[1]   THE GEOCHEMICAL BALANCE OF THE RARE-EARTH ELEMENTS AND NEODYMIUM ISOTOPES IN THE OCEANS [J].
BERTRAM, CJ ;
ELDERFIELD, H .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1993, 57 (09) :1957-1986
[2]  
Byrne R.H., 1996, HANDB PHYSI, DOI 10.1016/S0168-1273(96)23009-0
[3]  
CHEATHAM MM, 1993, SPECTROCHIM ACTA B, V48, pE487
[4]   RARE-EARTH ELEMENTS IN THE PACIFIC AND ATLANTIC OCEANS [J].
DEBAAR, HJW ;
BACON, MP ;
BREWER, PG ;
BRULAND, KW .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1985, 49 (09) :1943-1959
[6]   A simple method for the precise determination of >=40 trace elements in geological samples by ICPMS using enriched isotope internal standardisation [J].
Eggins, SM ;
Woodhead, JD ;
Kinsley, LPJ ;
Mortimer, GE ;
Sylvester, P ;
McCulloch, MT ;
Hergt, JM ;
Handler, MR .
CHEMICAL GEOLOGY, 1997, 134 (04) :311-326
[7]  
ELDERFIELD H, 1988, T R SOC LONDON A, V325, P105
[8]   PERFORMANCE-CHARACTERISTICS OF INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH HIGH-MASS RESOLUTION [J].
FELDMANN, I ;
TITTES, W ;
JAKUBOWSKI, N ;
STUEWER, D ;
GIESSMANN, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :1007-1014
[9]   HYDROTHERMAL SCAVENGING OF RARE-EARTH ELEMENTS IN THE OCEAN [J].
GERMAN, CR ;
KLINKHAMMER, GP ;
EDMOND, JM ;
MITRA, A ;
ELDERFIELD, H .
NATURE, 1990, 345 (6275) :516-518
[10]   HIGH-RESOLUTION ICP-MS - A NEW CONCEPT FOR ELEMENTAL MASS-SPECTROMETRY [J].
GIESSMANN, U ;
GREB, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (4-5) :186-193