An investigation into the use of electrochromic polymers in optical fibre gas sensors

被引:45
作者
Kondratowicz, B [1 ]
Narayanaswamy, R [1 ]
Persaud, KC [1 ]
机构
[1] UMIST, Dept Instrumentat & Analyt Sci, Manchester M60 1QD, Lancs, England
关键词
optical fibres; gas sensing; electrochromic polymers; optical sensors;
D O I
10.1016/S0925-4005(00)00723-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gas sensor based on the incorporation of electrochromic polymers into a fibre-optic device is described. The optical changes that occur when poly(4,4 ' -diphenylaminep-heptyloxy)benzylidene (PDPAHB) and poly(4,4 ' -diphenyliminep-heptyloxy)benzylidene (PDPMB) are exposed to different relative humidites (RH) or various ammonia concentrations (at 23 degreesC) have been investigated. Results of the exposure of the two polymers to 0-100% relative humidity show that the working range is between 50 and 100% RH. Reversal of the films was possible by flushing with dry air. Exposure of the two polymers to increasing ammonia concentrations results in a decrease in absorbance measured at 430.46 nm for PDPAHB and at 575.78 nm for PDPIHB. Reversal of the optical changes that occurred in both films due to the presence of ammonia, was not successful by flushing with dry air or HCl, respectively. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 26 条
[1]   Optical fibre sensor coated with porous silica layers for gas and chemical vapour detection [J].
Abdelghani, A ;
Chovelon, JM ;
Jaffrezic-Renault, N ;
Lacroix, M ;
Gagnaire, H ;
Veillas, C ;
Berkova, B ;
Chomat, M ;
Matejec, V .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :495-498
[2]  
[Anonymous], HDB CONDUCTING POLYM
[3]   TRANSDUCER MECHANISMS FOR OPTICAL BIOSENSORS .2. TRANSDUCER DESIGN [J].
ASHWORTH, DC ;
NARAYANASWAMY, R .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 30 (01) :21-31
[4]   NEW POLYANILINE DERIVATIVES - POLY(4,4'-DIPHENYLAMINE METHYLENES) AND POLY(4,4'-DIPHENYLIMINE METHINES) [J].
CHEN, WC ;
JENEKHE, SA .
MACROMOLECULES, 1992, 25 (22) :5919-5926
[5]  
DEMARCOS S, 1997, ANAL CHIM ACTA, V357, P247
[6]   FIBER OPTIC PH SENSORS PREPARED BY SOL-GEL IMMOBILIZATION TECHNIQUE [J].
DING, JY ;
SHAHRIARI, MR ;
SIGEL, GH .
ELECTRONICS LETTERS, 1991, 27 (17) :1560-1562
[7]  
Janata J., 1989, PRINCIPLES CHEM SENS
[8]   A chemiluminescence-based biosensor for metal ion detection [J].
Kamtekar, SD ;
Pande, R ;
Ayyagari, MS ;
Marx, KA ;
Kaplan, DL ;
Kumar, J ;
Tripathy, SK .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC MATERIALS SENSORS AND SYSTEMS, 1995, 3 (02) :79-83
[9]   ABSORPTION OF GASEOUS IODINE BY FILMS OF POLYTHIOPHENE [J].
KIM, D ;
REISS, H .
JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (13) :2728-2729
[10]  
Margolis J., 1989, CONDUCTIVE POLYM PLA