Accuracy of ultrasonography in predicting celiac disease

被引:30
作者
Fraquelli, M
Colli, A
Colucci, A
Bardella, MT
Trovato, C
Pometta, R
Pagliarulo, M
Conte, D
机构
[1] Osped Maggiore, IRCCS, Postgrad Sch Gastroenterol, I-20122 Milan, Italy
[2] Osped A Manzoni, Dept Internal Med, Lecco, Italy
关键词
D O I
10.1001/archinte.164.2.169
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Various ultrasonographic (US) signs have been reported in overt celiac disease (CD). The aim of this study was to investigate the diagnostic accuracy of 6 US parameters in predicting CD. Methods: One hundred sixty-two consecutive patients with chronic diarrhea (n = 105), iron deficiency anemia (n=25), or dyspepsia (n=32) underwent antiendomysial IgA antibody determination and duodenal biopsy. Moreover, US evaluation of 6 parameters (ie, fasting gallbladder volume, transverse diameter of small bowel loops, thickness of the small bowel wall, pattern of peristalsis, presence of free abdominal fluid, and diameter of the mesenteric lymph nodes) was done by 2 operators blind to the serological and histological findings. The pretest probability of CD was estimated to be between 5% and 10%. The percentage of agreement between US and histologic findings, the sensitivity, specificity, positive and negative likelihood ratios, and the posttest probability for positive and negative results were calculated. Results: Celiac disease was diagnosed in 12 patients (7.4%). An increased gallbladder volume, the presence of free fluid in the abdominal cavity, and enlarged mesenteric lymph nodes showed a specificity of 96%, 96%, and 97%, respectively (95% confidence intervals [CIs], 92%-99%, 93%-99%, and 95%-99%), whereas the presence of dilated small bowel loops with increased fluid content and increased peristalsis had a sensitivity of 92% and 83%, respectively (95% CIs, 76%-100% and 62%-100%). Eleven (92%) of the 12 patients with celiac disease and 35 (23%) of the 150 patients who did not have the disease had at least 1 US sign (P =.001); all of the US signs were concomitantly present in 4 patients with CD (33%) and I patient without CD (0.6%) (P=.001). Conclusion: Ultrasonographic evaluation can accurately predict CD but its place in the diagnostic algorithm depends upon the probability of the disease in the considered population.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 28 条
[1]  
[Anonymous], 1999, GASTROENTEROL GASTRO, DOI DOI 10.1016/S0016-5085(99)70512-3
[2]  
Black E, 1999, DIAGNOSTIC STRATEGIE, P1
[3]   ANTIENDOMYSIUM ANTIBODIES AND CELIAC-DISEASE - SOLVED AND UNSOLVED QUESTIONS - AN ITALIAN MULTICENTER STUDY [J].
CATALDO, F ;
VENTURA, A ;
LAZZARI, R ;
BALLI, F ;
NASSIMBENI, G ;
MARINO, V .
ACTA PAEDIATRICA, 1995, 84 (10) :1125-1131
[4]   CELIAC-DISEASE IN THE YEAR 2000 - EXPLORING THE ICEBERG [J].
CATASSI, C ;
RATSCH, IM ;
FABIANI, E ;
ROSSINI, M ;
BORDICCHIA, F ;
CANDELA, F ;
COPPA, GV ;
GIORGI, PL .
LANCET, 1994, 343 (8891) :200-203
[5]   AGA technical review on celiac sprue [J].
Ciclitira, PJ .
GASTROENTEROLOGY, 2001, 120 (06) :1526-1540
[6]  
COTTONE M, 1986, Rays (Rome), V11, P111
[7]   SONOGRAPHIC MEASUREMENT OF GALLBLADDER VOLUME [J].
DODDS, WJ ;
GROH, WJ ;
DARWEESH, RMA ;
LAWSON, TL ;
KISHK, SMA ;
KERN, MK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (05) :1009-1011
[8]   Fortnightly review - Coeliac disease [J].
Feighery, C .
BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7204) :236-239
[9]  
Fleiss J., 1981, STAT METHODS RATES P, P17
[10]  
Fraquelli M, 1999, AM J GASTROENTEROL, V94, P1866