摘要
The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material properties of the constituent tissues it is necessary to measure cross-sectional area (CSA). Problems associated with this include damage to the structure, inaccurate values for non-uniform shapes, labour intensive techniques or requirement of expensive equipment. We describe a non-destructive technique for measurement of tendon and ligament CSA based on that of Race and Amis (J. Biomech. 29 (1996) 1207). The modified technique uses aqueous rapid curing alginate dental impression paste, digital photography and computerised image analysis. This technique is quick and simple to carry out and provides accurate values (within 0.8%) for CSA which are reproducible (coefficient of variation= 1.42%). The technique is non-destructive and can be used on specimens with an irregular shape. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:605 / 608
页数:4
相关论文
共 9 条
[1]
The tensile strength of human tendons [J].
Cronkite, AE .
ANATOMICAL RECORD, 1936, 64 (02) :173-186
[2]
Gratz CM, 1931, J BONE JOINT SURG, V13, P334
[3]
A NEW METHOD FOR DETERMINING CROSS-SECTIONAL SHAPE AND AREA OF SOFT-TISSUES [J].
LEE, TQ ;
WOO, SLY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (02) :110-114
[4]
Noguchi Masahiko, 2002, J Orthop Sci, V7, P247, DOI 10.1007/s007760200041
[5]
NUNLEY R L, 1958, Am J Phys Med, V37, P256
[6]
Cross-sectional area measurement of soft tissue. A new casting method [J].
Race, A ;
Amis, AA .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1207-1212
[7]
THE MECHANICAL PROPERTIES OF RAT TAIL TENDON [J].
RIGBY, BJ ;
HIRAI, N ;
SPIKES, JD ;
EYRING, H .
JOURNAL OF GENERAL PHYSIOLOGY, 1959, 43 (02) :265-283
[8]
THE CROSS-SECTIONAL AREAS OF NORMAL EQUINE DIGITAL FLEXOR TENDONS DETERMINED ULTRASONOGRAPHICALLY [J].
SMITH, RKW ;
JONES, R ;
WEBBON, PM .
EQUINE VETERINARY JOURNAL, 1994, 26 (06) :460-465
[9]
WALKER LEON B., 1964, MED ELECTR AND BIOL ENGNG, V2, P31, DOI 10.1007/BF02474358