Subjective quality assessment of computed radiography hand images

被引:13
作者
Britton, CA
Gabriele, OF
Chang, TS
Towers, JD
Rubin, DA
Good, WF
Gur, D
机构
[1] Department of Radiology, University of Pittsburgh, Pittsburgh, PA
[2] A449 Scaife Hall, Department of Radiology, University of Pittsburgh, Pittsburgh
关键词
imaging; image quality; subjective assessment; computed radiography (CR);
D O I
10.1007/BF03168564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the sensitivity of a non-receiver-operating characteristic (ROC) study in assessing small differences of perceived image quality of hand images acquired by computed radiography (CR) and conventional screen-film systems, hand images were acquired on 12 patients with both conventional screen-film and CR. Each CR image was then processed with three different edge-enhancement algorithms. One conventional film and four CR images were then viewed side by side by five radiologists. Observers rated perceived image quality of each radiograph using a 10-category discrete scale. The study was repeated after 6 weeks using a different block randomization scheme. Despite the small sample size, significant differences (P < .05) in assigned image quality were detected among CR images acquired at low, medium, and high resolutions. Image processing routines did not fully compensate for differences in quality between conventional film and CR-acquired images. The quality rating of the reference conventional image was found to be dependent on the quality of images with which it was compared. Small, highly sensitive study designs can be used to identify radiologists' perceived differences in image quality. ''Reference'' or ''gold standard'' quality are important in such studies. Edge-enhancement schemes cannot fully compensate for perceived image quality degradations because of reduced image resolution. Copyright (C) 1996 by W.B. Saunders Company
引用
收藏
页码:21 / 24
页数:4
相关论文
共 8 条
[1]   STORAGE PHOSPHOR RADIOGRAPHS VS CONVENTIONAL FILMS - INTERPRETERS PERCEPTIONS OF DIAGNOSTIC QUALITY [J].
FUHRMAN, CR ;
GUR, D ;
GOOD, B ;
ROCKETTE, H ;
COOPERSTEIN, LA ;
FEIST, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1011-1014
[2]  
Good W F, 1994, J Digit Imaging, V7, P77
[3]   OPERATING AT THE DIAGNOSTIC MARGINS - IMAGE QUALITY CONSIDERATIONS [J].
GUR, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1341-1342
[4]  
GUR D, 1994, P SOC PHOTO-OPT INS, V2436, P70
[5]  
JONSSON A, 1994, ACTA RADIOL, V35, P311
[8]   PHOTOSTIMULABLE PHOSPHOR DIGITAL RADIOGRAPHY OF THE EXTREMITIES - DIAGNOSTIC-ACCURACY COMPARED WITH CONVENTIONAL RADIOGRAPHY [J].
WILSON, AJ ;
MANN, FA ;
MURPHY, WA ;
MONSEES, BS ;
LINN, MR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) :533-538