Analysis of lymph nodes for polyethylene particles in patients who have had a primary joint replacement

被引:28
作者
Shea, KG
Bloebaum, RD
Avent, JM
Birk, T
Samuelson, KM
机构
[1] VET ADM MED CTR, BONE & JOINT RES LAB, SALT LAKE CITY, UT 84148 USA
[2] LATTER DAY ST HOSP, DEPT ORTHOPAED SURG & PATHOL, SALT LAKE CITY, UT 84143 USA
关键词
D O I
10.2106/00004623-199604000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Polarized light microscopy has been used for more than forty years to identify polyethylene particles in histological specimens; however, few investigators have assessed the specificity of this technique. We examined specimens from dissected lymph nodes for the presence of strongly birefringent particles resembling polyethylene. Twenty-seven patients had dissection of lymph nodes after a total joint replacement (Group 1), and a control group of eighteen patients had dissection of lymph nodes before a total joint replacement (Group 2). Specimens from both groups of lymph nodes were examined under plain and polarized light. The presence of strongly birefringent particulate debris was graded from 0 to 4. Twenty-one (78 per cent) of the twenty-seven patients in Group 1 and eight of the eighteen patients in Group 2 had strongly birefringent particles in the lymph nodes. Our results demonstrate that, in the assessment of the systemic dissemination of polyethylene in the lymphoreticular system, polarized light microscopy has important limitations. More refined techniques employing polarized light and other methods of physical and chemical analysis may be necessary to identify polyethylene particles accurately within the lymphoreticular system and periprosthetic tissue.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 36 条
[1]  
[Anonymous], 1992, SOCIOLOGICA, V7
[2]  
ARMITAGE P, 1971, STATISTICAL METHODS, P434
[3]   REGIONAL DISSEMINATION OF WEAR DEBRIS FROM A TOTAL KNEE PROSTHESIS - A CASE-REPORT [J].
BAUER, TW ;
SALTARELLI, M ;
MCMAHON, JT ;
WILDE, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :106-111
[4]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[5]   COMPARATIVE INVESTIGATIONS OF REGIONAL LYMPH-NODES AND PSEUDOCAPSULES AFTER IMPLANTATION OF JOINT ENDOPROSTHESES [J].
BOS, I ;
JOHANNISSON, R ;
LOHRS, U ;
LINDNER, B ;
SEYDEL, U .
PATHOLOGY RESEARCH AND PRACTICE, 1990, 186 (06) :707-716
[6]   TISSUE DIGESTION FOR WEAR DEBRIS PARTICLE ISOLATION [J].
CAMPBELL, P ;
MA, S ;
SCHMALZRIED, T ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (04) :523-526
[7]  
CAMPBELL P, 1991, HIP ARTHROPLASTY, P555
[8]  
CHARNLEY J, 1963, LANCET, V2, P1379
[9]  
Charnley J., 1979, LOW FRICTION ARTHROP
[10]   TOTAL HIP REPLACEMENT FAILURES - HISTOLOGICAL EVALUATION [J].
CHAROSKY, CB ;
BULLOUGH, PG ;
WILSON, PD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (01) :49-58