Heat gain reduction by means of thermoelectric roof solar collector

被引:53
作者
Maneewan, S
Hirunlabh, J
Khedari, J
Zeghmati, B
Teekasap, S
机构
[1] King Mongkuts Univ Technol Thonburi, BSRC, Bangkok 10140, Thailand
[2] Univ Perpignan, Lab Mecan Acoust & Instrumentat, F-66860 Perpignan, France
[3] SE Asia Univ, Engn Management Program, Bangkok 10160, Thailand
关键词
ceiling heat transfer rate; economic; roof solar collector; TRNSYS; NATURAL VENTILATION; PERFORMANCE; CLIMATES; POWER;
D O I
10.1016/j.solener.2004.08.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a numerical investigation on attic heat gain reduction by using thermoelectric modules intearated in a conventional roof solar collector (RSC). This system, called thermoelectric roof solar collector (TERSC), is composed of a transparent glass, air gap, a copper plate, thermoelectric modules (TE) and rectangular fin heat sink. Due to the incident solar radiation, a temperature difference is created between the hot and cold sides of TE modules that generates a direct current. This current is used to drive a ventilating fan for cooling the TE-RSC and enhancing attic ventilation that reduces ceiling heat gain. The system performance was simulated using TRNSYS program with new TE and DC fan components developed by our team and compared to a common house. Simulation results using real house configuration showed that a TE-RSC unit of 0.0525m(2) surface area can generate about 9W under 972W/m(2) global solar radiation and 35 degrees C ambient temperature. The induced air change varied between 20 and 40 and the corresponding ceiling heat transfer rate reduction is about 3-5W/m(2). The annual electrical energy saving was about 362 kWh. Finally, economical calculations indicated that the payback period of the TE-RSC is 4.36 years and the internal rate of return is 22.05%. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 19 条
[1]   A roof solar chimney assisted by cooling cavity for natural ventilation in buildings in hot arid climates: An energy conservation approach in Al-Ain city [J].
Aboulnaga, MM .
RENEWABLE ENERGY, 1998, 14 (1-4) :357-363
[2]  
COKLI K, 2002, APPL THERM ENG, V23, P437
[3]   NEW RECOMMENDATIONS FOR BUILDING IN TROPICAL CLIMATES [J].
DEWAAL, HB .
BUILDING AND ENVIRONMENT, 1993, 28 (03) :271-285
[4]  
GRATIA E, 2002, ENERGY BUILDING, V43, P1
[5]   New configurations of a roof solar collector maximizing natural ventilation [J].
Hirunlabh, J ;
Wachirapuwadon, S ;
Pratinthong, N ;
Khedari, J .
BUILDING AND ENVIRONMENT, 2001, 36 (03) :383-391
[6]   Field measurements of performance of roof solar collector [J].
Khedari, J ;
Mansirisub, W ;
Chaima, S ;
Pratinthong, N ;
Hirunlabh, J .
ENERGY AND BUILDINGS, 2000, 31 (03) :171-178
[7]   A PV system enhanced the performance of roof solar collector [J].
Khedari, J ;
Ingkawanich, S ;
Waewsak, J ;
Hirunlabh, J .
BUILDING AND ENVIRONMENT, 2002, 37 (12) :1317-1320
[8]  
LAU PG, 1997, 16 INT C THERM, P536
[9]   Investigation on generated power of thermoelectric roof solar collector [J].
Maneewan, S ;
Khedari, J ;
Zeghmati, B ;
Hirunlabh, J ;
Eakburanawat, J .
RENEWABLE ENERGY, 2004, 29 (05) :743-752
[10]  
MANEEWAN S, 2003, EGAT J, V2, P36