Internal support of tissue-engineered cartilage

被引:43
作者
Arévalo-Silva, CA
Eavey, RD
Cao, YL
Vacanti, M
Weng, YL
Vacanti, CA
机构
[1] Massachusetts Eye & Ear Infirm, Dept Otolaryngol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Dept Otol & Laryngol, Boston, MA 02115 USA
[3] Univ Massachusetts, Med Ctr, Lab Tissue Engn, Dept Anesthesia, Worcester, MA USA
[4] Univ Massachusetts, Med Ctr, Dept Pathol, Worcester, MA USA
关键词
D O I
10.1001/archotol.126.12.1448
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Auricles previously created by tissue engineering in nude mice used a biodegradable internal scaffold to maintain the desired shape of an ear. However, the biodegradable scaffold incited a compromising inflammatory response in subsequent experiments in immunocompetent animals. Objective: To test the hypothesis that tissue-engineered autologous cartilage can be bioincorporated with a nonreactive, permanent endoskeletal scaffold. Materials and Methods: Auricular elastic cartilage was harvested from Yorkshire swine. The chondrocytes were isolated and suspended into a hydrogel (Pluronic F-127) at a cell concentration of 5 x 10(7) cells/mL. Nonbiodegradable endoskeletal scaffolds were formed with 1 of 5 polymers: (1) high-density polyethylene, (2) soft acrylic, (3) polymethylmethaclylate, (4) extrapurified Silastic, and (5) conventional Silastic. Three groups were studied: (1) a control group using only the 5 polymers, (2) the 5 polymers enveloped by Pluronic F-127 only, and (3) the implants coated with Pluronic F-127 seeded with chondrocytes. All constructs were implanted subdermally; implants containing cells were implanted into the same animal from which the cells had been islolated. The implants were harvested after 8 weeks of in vivo culture and histologically analyzed. Results: Only implants coated by hydrogel plus cells generated healthy new cartilage. With 3 polymers (high-density polyethylene, acrylic, and extrapurified Silastic), the coverage was nearly complete by elastic cartilage, with minimal fibrocartilage and minimal to no inflammatory reaction. The Food and Drug Administration-approved conventional Silastic implants resulted in fragments of fibrous tissue mixed with elastic cartilage plus evidence of chronic inflammation. The polymethylmethacrylate implant was intermediate in the amount of cartilage formed and degree of inflammation. Conclusions: This pilot technique combining tissue-engineered autologous elastic cartilage with a permanent biocompatible endoskeleton demonstrated success in limiting the inflammatory response to the scaffold, especially to high-density polyethylene, acrylic, and extrapurified Silastic. This model facilitates the potential to generate tissue of intricate shape, such as the human ear, by internal support.
引用
收藏
页码:1448 / 1452
页数:5
相关论文
共 13 条
[1]   Tissue engineering in urologic surgery [J].
Atala, A .
UROLOGIC CLINICS OF NORTH AMERICA, 1998, 25 (01) :39-+
[2]  
*BASF WYAND CORP C, 1975, PLURONIC POL TOX IRR
[3]   Autogenous tissue-engineered cartilage -: Evaluation as an implant material [J].
Britt, JC ;
Park, SS .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1998, 124 (06) :671-677
[4]   Transplantation of chondrocytes utilizing a polymer-cell construct to produce tissue-engineered cartilage in the shape of a human ear [J].
Cao, YL ;
Vacanti, JP ;
Paige, KT ;
Upton, J ;
Vacanti, CA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (02) :297-302
[5]  
Cao YL, 1998, J BIOMAT SCI-POLYM E, V9, P475
[6]  
HENRY RL, 1989, CRIT REV BIOCOMPAT, V5, P207
[7]  
IBARRA C, 1997, TRANSPLANT P, V29, P966
[8]   TISSUE ENGINEERING [J].
LANGER, R ;
VACANTI, JP .
SCIENCE, 1993, 260 (5110) :920-926
[9]   DESIGN OF NASOSEPTAL CARTILAGE REPLACEMENTS SYNTHESIZED FROM BIODEGRADABLE POLYMERS AND CHONDROCYTES [J].
PUELACHER, WC ;
MOONEY, D ;
LANGER, R ;
UPTON, J ;
VACANTI, JP ;
VACANTI, CA .
BIOMATERIALS, 1994, 15 (10) :774-778
[10]  
SAKATA J, 1994, TRANSPLANT P, V26, P3309