Colloidally stable novel copolymeric system for gene delivery in complete growth media

被引:27
作者
Agarwal, Ankit
Vilensky, Rita
Stockdale, Anne
Talmon, Yeshayahu
Unfer, Robert C.
Mallapragada, Surya K.
机构
[1] Iowa State Univ, Dept Chem Engn, Ames, IA 50011 USA
[2] Technion Israel Inst Technol, Dept Chem Engn, IL-32000 Haifa, Israel
[3] Iowa Canc Res Fdn, Urbandale, IA 50322 USA
基金
美国能源部;
关键词
block-copolymers; gene delivery; colloidal stability; Transfection; cytotoxicity;
D O I
10.1016/j.jconrel.2007.05.008
中图分类号
O6 [化学];
学科分类号
0703 [化学];
摘要
Novel cationic pentablock copolymers based on poly(2-diethylaminoethylmethacrylate) (PDEAEM) and Pluronic F127 were evaluated as non-viral gene delivery vectors from a physiochemical point of view for stability and transfection efficiency in complete growth media. A novel strategy was introduced to sterically stabilize the polyplexes of such Pluronic-based cationic polymers against aggregation with serum proteins. As cationic pentablock copolymers condense plasmid DNA into nanoplexes of 100-150 nm diameter, unmodified Pluronic added to the formulation self-assemble with the pentablock copolymers on the surface of polyplexes and shield the cationic PDEAEM chains of pentablock copolymers sterically with its long poly(ethyleneoxide) chains. These coated polyplexes formed colloidally stable dispersions of 150-250 nm diameter in serum-supplemented buffers. Cryo-TEM micrographs also showed that coating polyplexes with unmodified Pluronic reduced aggregation in serum proteins. Pentablock copolymers preserved the integrity of plasmid DNA condensed inside the polyplexes and provided efficient resistance to its degradation by nucleases. Though the total amount of DNA retained by ExGen 500((R)) polyplexes after nuclease digestion was more than that retained by pentablock copolymers, the amount of plasmid retained in supercoiled form was not significantly different. Polyplexes coated with unmodified Pluronic provided efficient transfection in SKOV3 cells in complete growth media, comparable to that provided by ExGen 5000 in terms of number of cells transfected, and one order less in terms of total transgene protein expressed. These sterically shielded polyplexes also exhibited much lower cytotoxicities than uncoated polyplexes of pentablock copolymers, and significantly lower than the cytotoxicity of ExGen 500((R)) at relevant concentrations. This colloidally stable, versatile, multi-component gene delivery system also forms thermo-reversible injectable hydrogels like Pluronics at physiological temperatures that can be used for sustained delivery of polyplexes, and is promising for systemic applications. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 37
页数:10
相关论文
共 40 条
[1]
Novel cationic pentablock copolymers as non-viral vectors for gene therapy [J].
Agarwal, A ;
Unfer, R ;
Mallapragada, SK .
JOURNAL OF CONTROLLED RELEASE, 2005, 103 (01) :245-258
[2]
Investigation of in vitro biocompatibility of novel pentablock copolymers for gene delivery [J].
Agarwal, Ankit ;
Unfer, Robert ;
Mallapragada, Surya K. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 81A (01) :24-39
[3]
Enhancement of the polycation-mediated DNA uptake and cell transfection with pluronic P85 block copolymer [J].
Astafieva, I ;
Maksimova, I ;
Lukanidin, E ;
Alakhov, V ;
Kabanov, A .
FEBS LETTERS, 1996, 389 (03) :278-280
[4]
Batrakova EV, 2001, J PHARMACOL EXP THER, V299, P483
[5]
Mechanism of sensitization of MDR cancer cells by Pluronic block copolymers: Selective energy depletion [J].
Batrakova, EV ;
Li, S ;
Elmquist, WF ;
Miller, DW ;
Alakhov, VY ;
Kabanov, AV .
BRITISH JOURNAL OF CANCER, 2001, 85 (12) :1987-1997
[6]
CONTROLLED ENVIRONMENT VITRIFICATION SYSTEM - AN IMPROVED SAMPLE PREPARATION TECHNIQUE [J].
BELLARE, JR ;
DAVIS, HT ;
SCRIVEN, LE ;
TALMON, Y .
JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1988, 10 (01) :87-111
[7]
Factors affecting blood clearance and in vivo distribution of polyelectrolyte complexes for gene delivery [J].
Dash, PR ;
Read, ML ;
Barrett, LB ;
Wolfert, M ;
Seymour, LW .
GENE THERAPY, 1999, 6 (04) :643-650
[8]
Synthesis and characterization of temperature and pH-responsive pentablock copolymers [J].
Determan, MD ;
Cox, JP ;
Seifert, S ;
Thiyagarajan, P ;
Mallapragada, SK .
POLYMER, 2005, 46 (18) :6933-6946
[9]
An overview of current delivery systems in cancer gene therapy [J].
El-Aneed, A .
JOURNAL OF CONTROLLED RELEASE, 2004, 94 (01) :1-14
[10]
Nomenclature for synthetic gene delivery systems [J].
Felgner, PL ;
Barenholz, Y ;
Behr, JP ;
Cheng, SH ;
Cullis, P ;
Huang, L ;
Jessee, JA ;
Seymour, L ;
Szoka, F ;
Thierry, AR ;
Wagner, E ;
Wu, G .
HUMAN GENE THERAPY, 1997, 8 (05) :511-512