Analysis of artemisinin by a packed-column supercritical fluid chromatography-atmospheric pressure chemical ionisation mass spectrometry technique

被引:25
作者
Dost, K [1 ]
Davidson, G
机构
[1] Univ Celal Bayar, Dept Chem, Manisa, Turkey
[2] Univ Nottingham, Sch Chem, Nottingham NG7 2RD, England
关键词
D O I
10.1039/b301342a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A packed-column supercritical fluid chromatography-atmospheric pressure chemical ionisation mass spectrometry method was studied for the determination of artemisinin from Artemisia annua L. extracts. The technique does not require any kind of derivatisation prior to the analysis. All samples were simply dissolved in methanol and injected into the mobile phase. Detection was achieved by using mass spectrometry with atmospheric pressure chemical ionisation. The ionisation technique is relatively soft and provides protonated molecular ion and informative structural fragmentation for the compound. Benzophenone was used as a chromatographic standard for the determination of the analytical reproducibility. The supercritical carbon dioxide mobile phase used in the system was modified by 10% methanol. The average absolute retention time was 3.54 min with a standard deviation of 0.017 min and a relative standard deviation of 0.4% with respect to benzophenone for the procedure. The correlation coefficient was 0.998 and detection limit 370 pg on column.
引用
收藏
页码:1037 / 1042
页数:6
相关论文
共 38 条
[1]   ARTEMISITENE, A NEW SESQUITERPENE LACTONE ENDOPEROXIDE FROM ARTEMISIA-ANNUA [J].
ACTON, N ;
KLAYMAN, DL .
PLANTA MEDICA, 1985, 51 (05) :441-442
[2]  
ASHCROFT AE, 1997, IONISATION METHODS O
[3]   Rapid determination of artemisinin and related analogues using high-performance liquid chromatography and an evaporative light scattering detector [J].
Avery, BA ;
Venkatesh, KK ;
Avery, MA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 730 (01) :71-80
[4]  
BROSSI A, 1988, J MED CHEM, V31, P648
[5]   A high-performance liquid chromatography analysis of plasma artemisinin using a glassy carbon electrode for reductive electrochemical detection [J].
Chan, KL ;
Yuen, KH ;
Jinadasa, S ;
Peh, KK ;
Toh, WT .
PLANTA MEDICA, 1997, 63 (01) :66-69
[6]   GERMPLASM VARIATION IN ARTEMISININ CONTENT OF ARTEMISIA-ANNUA USING AN ALTERNATIVE METHOD OF ARTEMISININ ANALYSIS FROM CRUDE PLANT-EXTRACTS [J].
CHARLES, DJ ;
SIMON, JE ;
WOOD, KV ;
HEINSTEIN, P .
JOURNAL OF NATURAL PRODUCTS, 1990, 53 (01) :157-160
[7]  
Chen HL, 2002, ELECTROPHORESIS, V23, P2865, DOI 10.1002/1522-2683(200209)23:17&lt
[8]  
2865::AID-ELPS2865&gt
[9]  
3.0.CO
[10]  
2-Q