Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-influence of inspiration level, nodule size, and segmentation performance

被引:110
作者
Gietema, Hester A. [1 ]
Schaefer-Prokop, Cornelia M.
Mali, Willem P. T. M.
Groenewegen, Gerard
Prokop, Mathias
机构
[1] Univ Med Ctr, Dept Radiol, NL-3584 CA Utrecht, Netherlands
[2] Univ Med Ctr, Dept Med Oncol, NL-3584 CA Utrecht, Netherlands
[3] Acad Med Ctr, Dept Radiol, Amsterdam, Netherlands
关键词
D O I
10.1148/radiol.2452061054
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively assess the precision of semiautomated volume measurements of pulmonary nodules at low-dose multi-detector row computed tomography (CT) and to investigate the influence of nodule size, segmentation algorithm, and inspiration level. Materials and Methods: This study had institutional review board approval; written informed consent was obtained from all patients. Between June 2004 and March 2005, 20 patients (15 men, five women; age range, 40-84 years; mean age, 57 years) referred for chest CT for known lung metastases under-went two additional low-dose chest CT examinations without contrast material (collimation, 16 x 0.75 mm). Between these examinations, patients got off and on the table to simulate the conditions for a follow-up examination. Noncalcified solid pulmonary nodules between 15 and 500 mm(3) that did not abut vessel or pleura were measured in both studies by using widely applied commercial semiautomated software. Interscan variability was established with the Bland and Altman approach. The impact of nodule shape (spherical or nonspherical) on measurement variability was assessed by using one-way analysis of variance, while the contributions of mean nodule volume and change in lung volume were investigated with univariate linear regression for completely (group A) and incompletely (group B) segmented nodules. Results: Two hundred eighteen eligible nodules (volume range, 16.4-472.7 mm(3); 106 spherical, 112 nonspherical) were evaluated. The 95% confidence interval for difference in measured volumes was -21.2%, 23.8% ( mean difference, 1.3%). The precision of nodule segmentation was highly dependent on nodule shape (P < .001) and was weakly related to inspiration level for completely segmented nodules (r = -0.20; P < .047), while mean nodule volume did not show any effect (P = .15 and P = .81 for group A and B nodules, respectively). Conclusion: Variation of semiautomated volume measurements of pulmonary nodules can be substantial. Segmentation represents the most important factor contributing to measurement variability, while change in inspiration level has only a weak effect for completely segmented nodules.
引用
收藏
页码:888 / 894
页数:7
相关论文
共 13 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements [J].
Gietema, Hester A. ;
Wang, Ying ;
Xu, Dongming ;
van Klaveren, Rob J. ;
deKoning, Harry ;
Scholten, Ernst ;
Verschakelen, Johny ;
Kohl, Gerhard ;
Oudkerk, Matthijs ;
Prokop, Mathias .
RADIOLOGY, 2006, 241 (01) :251-257
[3]   Growth rate of small lung cancers detected on mass CT screening [J].
Hasegawa, M ;
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Maruyama, Y ;
Watanabe, T .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1252-1259
[4]   Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images [J].
Hu, SY ;
Hoffman, EA ;
Reinhardt, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) :490-498
[5]   Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT [J].
Kostis, WJ ;
Yankelevitz, DF ;
Reeves, AP ;
Fluture, SC ;
Henschke, CI .
RADIOLOGY, 2004, 231 (02) :446-452
[6]   Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images [J].
Kostis, WJ ;
Reeves, AP ;
Yankelevitz, DF ;
Henschke, CI .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (10) :1259-1274
[7]   Pulmonary nodules: Preliminary experience with three-dimensional evaluation [J].
Revel, MP ;
Lefort, C ;
Bissery, A ;
Bienvenu, M ;
Aycard, L ;
Chatellier, G ;
Frija, G .
RADIOLOGY, 2004, 231 (02) :459-466
[8]   Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? [J].
Revel, MP ;
Bissery, A ;
Bienvenu, M ;
Aycard, L ;
Lefort, C ;
Frija, G .
RADIOLOGY, 2004, 231 (02) :453-458
[9]  
Therasse P, 2000, J NATL CANCER I, V92, P205, DOI 10.1093/jnci/92.3.205
[10]  
USUDA K, 1994, CANCER, V74, P2239, DOI 10.1002/1097-0142(19941015)74:8<2239::AID-CNCR2820740806>3.0.CO