Vertical displacement of the beating heart by the octopus tissue stabilizer:: Influence on coronary flow

被引:93
作者
Gründeman, PF [1 ]
Borst, C [1 ]
van Herwaarden, JA [1 ]
Verlaan, CWJ [1 ]
Jansen, EWL [1 ]
机构
[1] Univ Utrecht Hosp, Heart Lung Inst, Expt Cardiol Lab, Dept Cardiol, NL-3508 GA Utrecht, Netherlands
关键词
D O I
10.1016/S0003-4975(98)00226-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In beating heart coronary artery bypass graft operations, biventricular pump failure, as observed after exposure of the posterior circumflex branches by sternotomy, may originate from mechanical obstruction to coronary flow. Methods, Regional coronary blood Bow was measured in 8 anesthetized, paced, beta-blocked pigs, and the beating heart was fully retracted. Results. Displacement decreased cardiac output from 4.8 +/- 1.1 L/min (mean +/- standard deviation) to 2.8 +/- 1.2 L/min (p < 0.001), a 42% +/- 6% decrease that resulted in a decrease in mean arterial pressure by 48% +/- 6% (mean +/- standard error of the mean; p < 0.001) and a reduction in coronary blood flow in the left anterior descending coronary artery, the right coronary artery, and the circumflex coronary artery by 34% +/- 6%, 25% +/- 8%, and 50% +/- 10%, respectively (all p < 0.05 versus baseline). Relative circumflex coronary artery now was 20.1% +/- 8.3% lower than the combined relative value of left anterior descending coronary artery and right coronary artery flows (p = 0.046). Subsequent 20 degrees head-down tilt significantly increased ventricular preload pressures and restored cardiac output and mean arterial pressure as well as coronary blood flow. Conclusions. It is inferred that coronary blood flow was not mechanically obstructed during anterior displacement of the porcine beating heart, because augmentation of preloads by the maneuver of Trendelenburg restored coronary flow parallel to the recovery of cardiac output and mean arterial pressure while the heart remained retracted by 90 degrees. (C) 1998 by The Society of Thoracic Surgeons.
引用
收藏
页码:1348 / 1352
页数:5
相关论文
共 10 条
[1]  
Boonstra PW, 1997, ANN THORAC SURG, V63, P567
[2]   Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device (''Octopus'') [J].
Borst, C ;
Jansen, EWL ;
Tulleken, CAF ;
Grundeman, PF ;
Beck, HJM ;
vanDongen, JWF ;
Hodde, KC ;
Bredee, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1356-1364
[3]   Coronary artery bypass grafting without cardiopulmonary bypass [J].
Buffolo, E ;
deAndrade, JCS ;
Branco, JNR ;
Teles, CA ;
Aguiar, LF ;
Gomes, WJ .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :63-66
[4]   Left anterior descending coronary artery grafting via left anterior small thoracotomy without cardiopulmonary bypass [J].
Calafiore, AM ;
DiGiammarco, G ;
Teodori, G ;
Bosco, G ;
DAnnunzio, E ;
Barsotti, A ;
Maddestra, N ;
Paloscia, L ;
Vitolla, G ;
Sciarra, A ;
Fino, C ;
Contini, M .
ANNALS OF THORACIC SURGERY, 1996, 61 (06) :1658-1663
[5]   Hemodynamic changes during displacement of the beating heart by the Utrecht Octopus method [J].
Grundeman, PF ;
Borst, C ;
vanHerwaarden, JA ;
Beck, HJM ;
Jansen, EWL .
ANNALS OF THORACIC SURGERY, 1997, 63 (06) :S88-S92
[6]   Experimental off-pump grafting of a circumflex branch via sternotomy using a suction device [J].
Jansen, EWL ;
Grundeman, PF ;
Beck, HJM ;
Heijmen, RH ;
Borst, C .
ANNALS OF THORACIC SURGERY, 1997, 63 (06) :S93-S96
[7]   Less invasive off-pump CABG using a suction device for immobilization: the 'octopus' method [J].
Jansen, EWL ;
Grundeman, PF ;
Borst, C ;
Eefting, F ;
Diephuis, J ;
Nierich, A ;
Lahpor, JR ;
Bredee, JJ .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (03) :406-412
[8]  
JANSEN EWL, 1996, CIRCULATION S, V94, P52
[9]   MINIMALLY INVASIVE CORONARY-ARTERY BYPASS-GRAFTING - A NEW METHOD USING AN ANTERIOR MEDIASTINOTOMY [J].
ROBINSON, MC ;
GROSS, DR ;
ZEMAN, W ;
STEDJELARSEN, E .
JOURNAL OF CARDIAC SURGERY, 1995, 10 (05) :529-536
[10]  
SUBRAMANIAN VA, 1995, CIRCULATION S, V92, P645