Repeatability of a novel technique for in vivo measurement of three-dimensional patellar tracking using magnetic resonance Imaging

被引:33
作者
Fellows, RA
Hill, NA
MacIntyre, NJ
Harrison, MM
Ellis, RE
Wilson, DR
机构
[1] UBC, Dept Orthopaed, Div Orthopaed Engn Res, Vancouver, BC V5Z 4E3, Canada
[2] Vancouver Coastal Hlth Res Inst, Vancouver, BC, Canada
[3] Queens Univ, Dept Mech Engn, Kingston, ON, Canada
[4] Queens Univ, Human Mobil Res Ctr, Kingston, ON, Canada
[5] Queens Univ, Dept Surg, Kingston, ON, Canada
[6] Queens Univ, Sch Comp, Kingston, ON, Canada
关键词
patella; kinematics; MRI; repeatability; tracking; patellofemoral joint;
D O I
10.1002/jmri.20360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To determine the repeatability of a novel noninvasive MRI-based technique for measuring patellofemoral kinematics in vivo. Materials and Methods: The patellar kinematics measurement method relies on registering bone models (with associated coordinate systems) developed from a high resolution MRI scan to loaded bone positions derived from fast, low resolution MRI scans. The intrasubject variability, high resolution to low resolution registration error, and interexperimenter repeatability were quantified in experiments on three healthy subjects. Results: The intrasubject variability and registration error were within range of the accuracy of our procedure; specifically. less than or equal to 1.40 degrees for orientation and 0.81 mm for translation. The interexperimenter repeatability was less than or equal to 1.28 degrees for orientation, with the exception of patellar spin. and 0.68 mm for translation. Conclusion: Our novel measurement technique can measure three-dimensional patellar tracking noninvasively during loaded flexion in a repeatable mariner. Our results compare well to another noninvasive tracking protocol, fast phase-contrast MRJ, which has a reported subject interexam variability of 2.4 degrees or less for patellar orientation. A particular strength of our method is that axes and high-resolution bone models need only be determined once for intrasubject comparisons. The method is sufficiently accurate and repeatable to detect clinically significant changes in patellofemoral kinematics.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 20 条
[1]
In vitro measurement of the tracking pattern of the human patella [J].
Ahmed, AM ;
Duncan, NA ;
Tanzer, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02) :222-228
[2]
Increased knee joint loads during walking are present in subjects with knee osteoarthritis [J].
Baliunas, AJ ;
Hurwitz, DE ;
Ryals, AB ;
Karrar, A ;
Case, JP ;
Block, JA ;
Andriacchi, TP .
OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (07) :573-579
[3]
A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[4]
ATHLETIC INJURIES - COMPARISON BY AGE, SPORT, AND GENDER [J].
DEHAVEN, KE ;
LINTNER, DM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (03) :218-224
[5]
Elahi S, 2000, ARTHRITIS RHEUM, V43, P1874, DOI 10.1002/1529-0131(200008)43:8<1874::AID-ANR25>3.0.CO
[6]
2-2
[7]
FELLOWS RA, IN PRESS J BIOMECH
[8]
THE EPIDEMIOLOGY OF KNEE OSTEOARTHRITIS - RESULTS FROM THE FRAMINGHAM OSTEOARTHRITIS STUDY [J].
FELSON, DT .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1990, 20 (03) :42-50
[9]
GROOD ES, 1994, BIOMECH ENG, V105, P136
[10]
Measurement of patellar tracking: Assessment and analysis of the literature [J].
Katchburian, MV ;
Bull, AMJ ;
Shih, YF ;
Heatley, FW ;
Amis, AA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (412) :241-259