A microlocal analytical technique using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was developed to investigate elemental diffusion at the interface of NiCrAlY-based coatings on high-temperature alloys. The surface of the cross section of alloyed sample was scanned with a focused laser beam (diameter of laser crater, 25 mu m; wavelength, 213 nm; laser power density, 10(11) W cm(-2)), and the laser ablation system was coupled to a double-focusing sector field ICP-MS. The capabilities of LA-ICP-MS using "linescan'' and "single point'' mode at laser energies of 2 and 4 mJ were compared. Alloy certified reference material (CRM) BAM-328-1 (BAM-Bundesanstalt fur Materialprufung, Berlin, Germany) with a similar matrix composition to the samples investigated was employed to determine the relative sensitivity coefficients (RSCs) of chemical elements to quantify the analytical data. The RSCs of analytes measured by LA-ICP-MS in alloy CRM vary between 0.2 and 2. In addition, other calibration procedures involving calibration curves and solution-based calibration were considered. LA-ICP-MS was used to study the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air (300, 1000, 5000, 15 000 hours) at a temperature of 980 degrees C, whereby an increasing loss of aluminium due to diffusion from coating into the high-temperature base alloy was observed. Furthermore, the diffusion of several substrate alloying elements (e.g., Co, Ta, Mo, W) into the coating after annealing was found, which could be the reason for the alteration of mechanical properties (high-temperature stability) or oxidation performance or both.
引用
收藏
页码:918 / 923
页数:6
相关论文
共 23 条
[1]   Inorganic mass spectrometric methods for trace, ultratrace, isotope, and surface analysis [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :1-35
[2]   Determination of Ag, Tl, and Pb in few milligrams of platinum nanoclusters by on-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Pickhardt, C ;
Pompe, W .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 237 (01) :13-17
[3]   Applications of inductively coupled plasma mass spectrometry and laser ablation inductively coupled plasma mass spectrometry in materials science [J].
Becker, JS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :1805-1820
[4]   State-of-the-art in inorganic mass spectrometry for analysis of high-purity materials [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (2-3) :127-150
[5]   Studies of LA-ICP-MS on quartz glasses at different wavelengths of a Nd:YAG laser [J].
Becker, JS ;
Tenzler, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :637-640
[6]  
BECKER JS, 2005, IN PRESS ANAL CHEM
[7]   Profiling of patterned metal layers by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) [J].
Bi, M ;
Ruiz, AM ;
Gornushkin, I ;
Smith, BW ;
Winefordner, JD .
APPLIED SURFACE SCIENCE, 2000, 158 (3-4) :197-204
[8]   Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects [J].
Durrant, SF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1385-1403
[9]   Quantitative analysis of silicates using LA-ICP-MS with liquid calibration [J].
Halicz, L ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1539-1545
[10]   Interference phenomena at transparent layers in glow discharge optical emission spectrometry [J].
Hoffmann, V ;
Kurt, R ;
Kämmer, K ;
Thielsch, R ;
Wirth, T ;
Beck, U .
APPLIED SPECTROSCOPY, 1999, 53 (08) :987-990