Pore fouling of microfiltration membranes by activated

被引:84
作者
Fang, HHP [1 ]
Shi, XL [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Environm Biotechnol Lab, Hong Kong, Hong Kong, Peoples R China
关键词
activated sludge; fouling; membrane; microfiltration; pore;
D O I
10.1016/j.memsci.2005.04.029
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Pore fouling of four microfiltration membranes was investigated for the filtration of activated sludge using sonication as the means to remove the cake layer from membrane surface. Results show that pore fouling was affected by membrane's microstructure, pore openings and hydrophilicity. For the track-etched polycarbonate (PC) membrane, there was no measurable pore resistance (R-p) to filtration. For the three membranes of sponge-like microstructure, the respective R-p values were 0.3 x 10(11), 1.3 x 10(11), and 16.4 x 10(11), m(-1) for polyvinylidene fluoride (PVDF), mixed cellulose esters (MCE), and polyethersulfone (PES). The PES membrane had the highest Rp due to its large pore openings (18-20 mu m), whereas NICE had higher Rp than PVDF because of its higher hydrophilicity. The R-p of PES membrane accounted for 86% of the total resistance for its filtration of activated sludge; the corresponding values were merely 2% for PVDF and 11% for NICE. It increased with the suspended solids level of the activated sludge to the power of 0.56. Results further demonstrated that R-p-dominant type of membranes, such as PES, was unsuitable for the membrane bioreactors. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 35 条
[1]   Microfiltration of activated sludge wastewater - the effect of system operation parameters [J].
Bai, RB ;
Leow, HF .
SEPARATION AND PURIFICATION TECHNOLOGY, 2002, 29 (02) :189-198
[2]   Fouling characterisation in membrane bioreactors [J].
Bouhabila, E ;
Ben Aïm, R ;
Buisson, H .
SEPARATION AND PURIFICATION TECHNOLOGY, 2001, 22-3 (1-3) :123-132
[3]   MEMBRANE BIOREACTOR ON DOMESTIC WASTE-WATER TREATMENT SLUDGE PRODUCTION AND MODELING APPROACH [J].
CHAIZE, S ;
HUYARD, A .
WATER SCIENCE AND TECHNOLOGY, 1991, 23 (7-9) :1591-1600
[4]   Membrane filtration characteristics in membrane-coupled activated sludge system - the effect of physiological states of activated sludge on membrane fouling [J].
Chang, IS ;
Lee, CH .
DESALINATION, 1998, 120 (03) :221-233
[5]   HOUSEHOLD MEMBRANE BIOREACTOR IN DOMESTIC WASTE-WATER TREATMENT [J].
CHIEMCHAISRI, C ;
YAMAMOTO, K ;
VIGNESWARAN, S .
WATER SCIENCE AND TECHNOLOGY, 1993, 27 (01) :171-178
[6]   Membrane fouling mechanisms in the membrane-coupled anaerobic bioreactor [J].
Choo, KH ;
Lee, CH .
WATER RESEARCH, 1996, 30 (08) :1771-1780
[7]   Evaluation of cell behaviour related to physico-chemical properties of polymeric membranes to be used in bioartificial organs [J].
De Bartolo, L ;
Morelli, S ;
Bader, A ;
Drioli, E .
BIOMATERIALS, 2002, 23 (12) :2485-2497
[8]   Contribution of various constituents of activated sludge to membrane bioreactor fouling [J].
Defrance, L ;
Jaffrin, MY ;
Gupta, B ;
Paullier, P ;
Geaugey, V .
BIORESOURCE TECHNOLOGY, 2000, 73 (02) :105-112
[9]   Ultrafiltration of activated sludge with ceramic membranes in a cross-flow membrane bioreactor process [J].
Fan, XJ ;
Urbain, V ;
Qian, Y ;
Manem, J .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (10-11) :243-250
[10]   MICROBIAL STRUCTURE AND ACTIVITY OF UASB GRANULES TREATING DIFFERENT WASTEWATERS [J].
FANG, HHP ;
CHUI, HK ;
LI, YY .
WATER SCIENCE AND TECHNOLOGY, 1994, 30 (12) :87-96