Inclusion of a non-immunoglobulin binding protein in two-site ELISA for quantification of human serum proteins without interference by heterophilic serum antibodies

被引:32
作者
Andersson, M
Rönnmark, J
Areström, I
Nygren, PÅ
Ahlborg, N
机构
[1] Mabtech, SE-13128 Nacka Strand, Sweden
[2] Royal Inst Technol, Dept Biotechnol, AlbaNova Univ Ctr, SE-10691 Stockholm, Sweden
[3] Univ Stockholm, Dept Immunol, SE-10691 Stockholm, Sweden
关键词
ELISA; immunoassay; heterophilic antibodies; affibody;
D O I
10.1016/j.jim.2003.09.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of human serum molecules with two-site ELISA can be biased by the presence of human heterophilic anti-animal immunoglobulin antibodies (HAIA) that cause false-positive signals by cross-linking the monoclonal (mAb) and/or polyclonal antibodies (pAb) used for the pre- (capture) and post-analyte steps (detection). To evaluate a novel ELISA format designed to avoid interference by HAIA, a target-specific non-immunoglobulin (Ig) affinity protein (affibody) was used to replace one of the antibodies. First, a human IgA-binding affibody (Z(IgA)) selected by phage display technology from a combinatorial library of a single Staphylococcus aureus protein A domain was used. The detection range of IgA standard using an ELISA based on Z(IgA) for capture and goat pAb against IgA (pAb(IgA)) for detection was comparable with that of using pAb(IgA) for both capture and detection. Secondly, another affibody (Z(Apo)) was combined with mAb and used to detect recombinant human apolipoprotein A-1. The affibody/antibody ELISAs were also used to quantify human serum levels of IgA and apolipoprotein A1. To verify that human serum did not cause false-positive signals in the affibody/antibody ELISA format, the ability of human serum to cross-link affibodies, mAb (mouse or rat) and/or pAb (goat) displaying non-matched specificities was assessed; affibodies and antibodies were not cross-linked whereas all combinations of mAb and/or pAb were cross-linked. The combination of affibodies and antibodies for analysis of human serum molecules represents a novel two-site ELISA format which precludes false-positive signals caused by HAIA. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 234
页数:10
相关论文
共 27 条
[1]   COMPETITIVE ENZYME-LINKED IMMUNOSORBENT-ASSAY (ELISA) FOR THE QUANTITATION OF APOLIPOPROTEIN A-I USING A MONOCLONAL-ANTIBODY [J].
BOJANOVSKI, M ;
GREGG, RE ;
WILSON, DM ;
BREWER, HB .
CLINICA CHIMICA ACTA, 1988, 178 (02) :159-169
[2]  
BOSCATO LM, 1988, CLIN CHEM, V34, P27
[3]  
Butler SA, 2001, CLIN CHEM, V47, P1332
[4]   ISOLATION OF HIGH-AFFINITY HUMAN-ANTIBODIES DIRECTLY FROM LARGE SYNTHETIC REPERTOIRES [J].
GRIFFITHS, AD ;
WILLIAMS, SC ;
HARTLEY, O ;
TOMLINSON, IM ;
WATERHOUSE, P ;
CROSBY, WL ;
KONTERMANN, RE ;
JONES, PT ;
LOW, NM ;
ALLISON, TJ ;
PROSPERO, TD ;
HOOGENBOOM, HR ;
NISSIM, A ;
COX, JPL ;
HARRISON, JL ;
ZACCOLO, M ;
GHERARDI, E ;
WINTER, G .
EMBO JOURNAL, 1994, 13 (14) :3245-3260
[5]   Affinity maturation of a Taq DNA polymerase specific affibody by helix shuffling [J].
Gunneriusson, E ;
Nord, K ;
Uhlén, M ;
Nygren, PÅ .
PROTEIN ENGINEERING, 1999, 12 (10) :873-878
[6]  
HAMILTON RG, 1989, MONOGR ALLERGY, V26, P27
[7]   An in vitro selected binding protein (affibody) shows conformation-dependent recognition of the respiratory syncytial virus (RSV) G protein [J].
Hansson, M ;
Ringdahl, J ;
Robert, A ;
Power, U ;
Goetsch, L ;
Nguyen, TN ;
Uhlén, M ;
Ståhl, S ;
Nygren, PÅ .
IMMUNOTECHNOLOGY, 1999, 4 (3-4) :237-252
[8]   The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs [J].
Hennig, C ;
Rink, L ;
Fagin, U ;
Jabs, WJ ;
Kirchner, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 235 (1-2) :71-80
[9]  
HUNTER WM, 1980, LANCET, V2, P1136
[10]   Falsely elevated digoxin level of 45.9 ng/mL due to interference from human antimouse antibody [J].
Ingels, M ;
Rangan, C ;
Morfin, JP ;
Williains, SR ;
Clark, RF .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2000, 38 (03) :343-345