Recombinant Microdochium nivale carbohydrate oxidase and its application in an amperometric glucose sensor

被引:17
作者
Kulys, J
Tetianec, L
Schneider, P
机构
[1] Inst Biochem, LT-2600 Vilnius, Lithuania
[2] Novo Nordisk AS, DK-2880 Bagsvaerd, Denmark
关键词
biosensor; carbohydrate; glucose; oxidase; Microdochium nivale; Aspergillus niger; mediator;
D O I
10.1016/S0956-5663(01)00128-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Biosensors containing recombinant carbohydrate oxidase from Microdochium nivale (rMnO) were developed by means of either chemically modified carbon paste or graphite electrode. 1-(N,N-dimethylamine)-4-(4-morpholine)benzene (AMB) and 1,1'-dimethylferrocene (DMFc) have been used as mediators. The biosensors showed a linear calibration graph up to 18 mM of glucose when operated at 0.04-0.36 V versus a saturated calomel electrode. Almost no change was detected in the sensitivity of the biosensors at pH 7.2-8.1. The biosensors responded to other aldoses in the D-configuration, however, maximal sensitivity of the biosensor was towards D-glucose. The biosensor did not response to polyhydroxylic compounds such as D-mannitol, D-sorbitol and inositol. The advantages of the biosensors based on rMnO in comparison to Aspergillus niger glucose oxidase is a wider linear range, low sensitivity to oxygen and (in some cases) broad specificity. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 15 条
[1]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[2]   QUINOPROTEIN GLUCOSE-DEHYDROGENASE AND ITS APPLICATION IN AN AMPEROMETRIC GLUCOSE SENSOR [J].
DCOSTA, EJ ;
HIGGINS, IJ ;
TURNER, APF .
BIOSENSORS, 1986, 2 (02) :71-87
[3]  
FREDERICK KR, 1990, J BIOL CHEM, V265, P3793
[4]   THE 3D STRUCTURE OF GLUCOSE-OXIDASE FROM ASPERGILLUS-NIGER - IMPLICATIONS FOR THE USE OF GOD AS A BIOSENSOR ENZYME [J].
HECHT, HJ ;
SCHOMBURG, D ;
KALISZ, H ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) :197-203
[5]   LONG-TERM RESPONSE OF AN INTEGRATED CARBON-PASTE BASED GLUCOSE BIOSENSOR [J].
KULYS, J ;
HANSEN, HE .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :285-294
[6]   Membrane covered carbon paste electrode for the electrochemical determination of peroxidase and microperoxidase in a flow system [J].
Kulys, J ;
Drungiliene, A ;
Wollenberger, U ;
Scheller, F .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (02) :227-232
[7]   STUDY OF THE NEW ELECTRON-TRANSFER MEDIATORS IN GLUCOSE-OXIDASE CATALYSIS [J].
KULYS, J ;
BUCHRASMUSSEN, T ;
BECHGAARD, K ;
RAZUMAS, V ;
KAZLAUSKAITE, J ;
MARCINKEVICIENE, J ;
CHRISTENSEN, JB ;
HANSEN, HE .
JOURNAL OF MOLECULAR CATALYSIS, 1994, 91 (03) :407-420
[8]  
KULYS J, 1990, ADV BIOSENSORS, V1, P107
[9]  
KULYS J, 2001, IN PRESS J MOL CATAL
[10]   Trends in electrochemical biosensors [J].
Magner, E .
ANALYST, 1998, 123 (10) :1967-1970