Lack of agreement between left ventricular volumes and ejection fraction determined by two-dimensional echocardiography and contrast cineangiography in postinfarction patients

被引:31
作者
Bernard, Y [1 ]
Meneveau, N [1 ]
Boucher, S [1 ]
Magnin, D [1 ]
Anguenot, T [1 ]
Schiele, F [1 ]
Vuillemenot, A [1 ]
Bassand, JP [1 ]
机构
[1] Hop Univ Jean Minjoz, F-25030 Besancon, France
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2001年 / 18卷 / 02期
关键词
left ventricular volumes; left ventricular systolic function; two-dimensional echocardiography;
D O I
10.1046/j.1540-8175.2001.00113.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess the agreement between left ventricular (LV) volumes and ejection fraction (EF) determined by two-dimensional echocardiography (2-D echo) and by cineangiography in postinfarction patients. Design: LV end-diastolic and end-systolic volumes indexed (EDVI and ESVI) to body surface area as well as EF were determined by both methods in all patients. Setting: Multicenter trial conducted in five university hospitals. Patients: 63 patients, 61 male, two female, mean age 55.5 +/- 10.4 years, suffering from a recent myocardial infarction. Eighty-one pairs of measurements were available. Methods: The results of biplane 2 D echo measures, using apical four-chamber (4C) and two-chamber (2C) views were compared to those of a 30 degrees right anterior oblique cineangiography projection, using either the apical method of discs or the area-length 2-D echo method. Moreover, eyeball EF was estimated at 2-D echo and cineangiography, and was compared to the conventional methods. The agreement between results was assessed by the Bland and Altman, method. Results: The agreement between 2-D echo and cineangiography results was poor. Mean differences (MD) were -21.8 EDVI, ml/m(2)), -9.5 (ESVI, ml/m(2)), and -0.9 (EF: %, respectively for 2-D echo method of discs versus cineangiography, and -23.2, -9.3 and -5.7 for area-length 2-D echo versus cineangiography. For EF (%), MD was -3.6 for eyeball cineangiography versus cineangiography, -1.3 for eyeball 2-D echo versus method of discs, and +0.30 for eyeball 2 D echo versus area-length 2-D echo, respectively. Two-dimensional echo is likely to underestimate LV volumes compared to cineangiography, especially for Largest volumes. Even. for EF discrepancies are large, with a lack of agreement of 21%-25% between conventional methods, but agreement is better between eyeball EF and usual methods. Conclusions: Even with modern echocardiographic devices, agreement between 2-D echo and cineangiography-derived LV volumes and EF remains moderate, and both methods must not be considered interchangeable in, clinical practice.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 30 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
*BSI, 1979, PREC TEST METH, V1
[3]   MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION BY MECHANICAL CROSS-SECTIONAL ECHOCARDIOGRAPHY [J].
CARR, KW ;
ENGLER, RL ;
FORSYTHE, JR ;
JOHNSON, AD ;
GOSINK, B .
CIRCULATION, 1979, 59 (06) :1196-1206
[4]   Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging [J].
Chuang, ML ;
Hibberd, MG ;
Salton, CJ ;
Beaudin, RA ;
Riley, MF ;
Parker, RA ;
Douglas, PS ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) :477-484
[5]   REPRODUCIBILITY OF ANGIOGRAPHIC LEFT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
COHN, PF ;
LEVINE, JA ;
BERGERON, GA ;
GORLIN, R .
AMERICAN HEART JOURNAL, 1974, 88 (06) :713-720
[6]   REPRODUCIBILITY OF LEFT-VENTRICULAR AREA AND VOLUME MEASUREMENTS USING A COMPUTER ENDOCARDIAL EDGE-DETECTION ALGORITHM IN NORMAL SUBJECTS [J].
CONETTA, DA ;
GEISER, EA ;
OLIVER, LH ;
MILLER, AB ;
CONTI, CR .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (15) :947-952
[7]   EFFECTS OF HEART-RATE CHANGES ON LEFT-VENTRICULAR VOLUME AND EJECTION FRACTION - A TWO-DIMENSIONAL ECHOCARDIOGRAPHIC STUDY [J].
ERBEL, R ;
SCHWEIZER, P ;
KREBS, W ;
LANGEN, HJ ;
MEYER, J ;
EFFERT, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (04) :590-597
[8]   ASSESSMENT OF LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES BY REAL-TIME, 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON OF CINEANGIOGRAPHIC AND RADIONUCLIDE TECHNIQUES [J].
FOLLAND, ED ;
PARISI, AF ;
MOYNIHAN, PF ;
JONES, DR ;
FELDMAN, CL ;
TOW, DE .
CIRCULATION, 1979, 60 (04) :760-766
[9]   REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GORDON, EP ;
SCHNITTGER, I ;
FITZGERALD, PJ ;
WILLIAMS, P ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) :506-513
[10]  
GUERET P, 1991, ARCH MAL COEUR VAISS, V84, P21