Changes in ultrasound properties of porcine kidney tissue during heating

被引:65
作者
Worthington, AE
Sherar, MD
机构
[1] Univ Toronto, Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
ultrasound; ultrasonic tissue characterization; backscatter; attenuation; thermal therapy; cancer;
D O I
10.1016/S0301-5629(01)00354-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Changes in the ultrasound (US) attenuation and backscatter of fresh pig kidney were measured as the tissue was heated. The objective was to use these changes to predict how an US image mould change in real-time with a view to its use as a monitoring tool for minimally invasive thermal therapy (MTTT), Separate samples of fresh pig kidney were heated from 37 degreesC to temperatures of 45 degrees, 50 degrees, 55 degrees, 60 degrees and 65 degrees with warm water. Measurements were made over the frequency range from 3.5 MHz to 7.0 MHz during 30-min heating experiments. A general increase in attenuation magnitude (dB/cm) and slope (dB/cm-MHz) was observed at temperatures of 55 degreesC or greater. Little change in backscatter power was observed during heating to 45 degreesC. At higher temperatures, the changes in backscatter showed a more complex pattern throughout the experiments, but still showed a trend of increase to a greater value at the end of heating than at the start. This backscatter increase was greater at higher temperatures, The net effect of the changes in US properties suggests that it may be possible to use diagnostic US to monitor, in real-time, MITT in kidney. (E-mail: sherar@oci.utoronto.ca) (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:673 / 682
页数:10
相关论文
共 30 条
[1]  
BAMBER J C, 1977, Ultrasound in Medicine and Biology, V3, P15, DOI 10.1016/0301-5629(77)90116-8
[2]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[3]  
Bosniak M A, 1995, Semin Urol Oncol, V13, P267
[4]   ACOUSTIC PROPERTIES OF LESIONS GENERATED WITH AN ULTRASOUND THERAPY SYSTEM [J].
BUSH, NL ;
RIVENS, I ;
TERHAAR, GR ;
BAMBER, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :789-801
[5]  
Chan David, 1999, Journal of Endourology, V13, pA14
[6]   SIMPLE EQUATIONS FOR THE SPEED OF SOUND IN NEPTUNIAN WATERS [J].
COPPENS, AB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 69 (03) :862-863
[7]   SOME EFFECTS OF TIME POSTMORTEM ON ULTRASONIC TRANSMISSION THROUGH TISSUE UNDER DIFFERENT MODES OF HANDLING [J].
CROSBY, BC ;
MACKAY, RS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1978, 25 (01) :91-92
[8]   Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose [J].
Damianou, CA ;
Sanghvi, NT ;
Fry, FJ ;
MaassMoreno, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (01) :628-634
[9]   FREQUENCY-DEPENDENCE OF ULTRASOUND ATTENUATION AND BACKSCATTER IN BREAST-TISSUE [J].
DASTOUS, FT ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (10) :795-808
[10]  
Duck F. A., 1990, PHYSICAL PROPERTIES, P75