Detection of intraoperative incidents by electronic scanning of computerized anesthesia records - Comparison with voluntary reporting

被引:139
作者
Sanborn, KV
Castro, J
Kuroda, M
Thys, DM
机构
[1] Department of Anesthesiology, St. luke'S-roosevelt Hospital Center, New York, NY 10025
关键词
compliance; computers; complications; bradycardia; death; hypertension; hypotension; hypothermia; hypoxia; tachycardia; critical events; monitoring; intraoperative; records; anesthesia;
D O I
10.1097/00000542-199611000-00004
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The use of a computerized anesthesia information management system provides an opportunity to scan case records electronically for deviations from specific Limits for physiologic variables. Anesthesia department policy may define such deviations as intraoperative incidents and may require anesthesiologists to report their occurrence. The actual incidence of such events is not known. Neither is the level of compliance with voluntary reporting. Methods: Using automated anesthesia record-keeping with long-term storage, physiologic data were recorded every 15 s from 5,454 patients undergoing noncardiothoracic surgery. Recorded measurements of blood pressure, heart rate, arterial oxygen saturation, and temperature were electronically analyzed for deviations from defined limits. The computer system also was used by anesthesiologists to report voluntarily those deviations as intraoperative incidents. For each electronically detected incident: 1) the complete automated anesthesia record was examined by two senior anesthesiologists who, by consensus, eliminated case records with artifact or in which context suggested that the incident was not clinically relevant, and 2) the anesthesia information management system database was checked for voluntary reporting. Results: In 473 automated anesthesia records, 494 incidents were found by electronic scanning of 5,454 automated anesthesia records. Sixty intraoperative incidents were eliminated, 25 due to artifact and 35 due to context. When the remaining 434 intraoperative incidents were checked for voluntary reporting, 18 (4.1%) matching voluntary reports were found. All intraoperative incidents that were reported voluntarily also were detected by electronic scanning. Based on a 10% sample, the sensitivity rate of electronic scanning was 97.2% (35/36), and the specificity rate was 98.4% (427/434). Among 413 cases with electronically detected intraoperative incidents, there were 29 deaths (7.0%), whereas there were only 79 deaths (1.6%) among 5,041 cases without incidents (chi(2) = 58.5, P < 0.001). Conclusions: The use of an anesthesia information manage ment system facilitated analysis of intraoperative physiologic data and identified certain intraoperative incidents with high sensitivity and specificity. A low level of compliance with voluntary reporting of defined intraoperative incidents was found for all anesthesiologists studied. Finally, there was a strong association between intraoperative incidents and in-hospital mortality.
引用
收藏
页码:977 / 987
页数:11
相关论文
共 36 条
  • [1] BERGER JJ, 1984, ANESTH ANALG, V63, P647
  • [2] NORMAL FLUCTUATION OF PHYSIOLOGICAL CARDIOVASCULAR VARIABLES DURING ANESTHESIA AND THE PHENOMENON OF SMOOTHING
    BLOCK, FE
    [J]. JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 141 - 145
  • [3] BROWNER WS, 1994, WESTERN J MED, V161, P572
  • [4] COHEN MM, 1986, CAN J ANAESTH, V33, P22, DOI 10.1007/BF03010904
  • [5] THE CANADIAN 4-CENTER STUDY OF ANESTHETIC OUTCOMES .2. CAN OUTCOMES BE USED TO ASSESS THE QUALITY OF ANESTHESIA CARE
    COHEN, MM
    DUNCAN, PG
    POPE, WDB
    BIEHL, D
    TWEED, WA
    MACWILLIAM, L
    MERCHANT, RN
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (05): : 430 - 439
  • [6] THE CANADIAN 4-CENTER STUDY OF ANESTHETIC OUTCOMES .1. DESCRIPTION OF METHODS AND POPULATIONS
    COHEN, MM
    DUNCAN, PG
    TWEED, WA
    BIEHL, D
    POPE, WDB
    PERRY, M
    MERCHANT, RN
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (05): : 420 - 429
  • [7] DIFFERENCES BETWEEN HANDWRITTEN AND AUTOMATIC BLOOD-PRESSURE RECORDS
    COOK, RI
    MCDONALD, JS
    NUNZIATA, E
    [J]. ANESTHESIOLOGY, 1989, 71 (03) : 385 - 390
  • [8] AN ANALYSIS OF MAJOR ERRORS AND EQUIPMENT FAILURES IN ANESTHESIA MANAGEMENT - CONSIDERATIONS FOR PREVENTION AND DETECTION
    COOPER, JB
    NEWBOWER, RS
    KITZ, RJ
    [J]. ANESTHESIOLOGY, 1984, 60 (01) : 34 - 42
  • [9] Costanza M E, 1992, J Am Board Fam Pract, V5, P143
  • [10] EDSALL D, 1991, QUAL REV B JUN, P182