Clinical outcomes of compromised side branch (stent jail) after coronary stenting with the NIR stent

被引:23
作者
Bhargava, B [1 ]
Waksman, R [1 ]
Lansky, AJ [1 ]
Kornowski, R [1 ]
Mehran, R [1 ]
Leon, MB [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Cardiac Catheterizat Lab, Washington, DC 20010 USA
关键词
ischemic heart disease; angioplasty; NIR stents; side branch;
D O I
10.1002/ccd.1287
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Acute side-branch (SB) compromise or occlusion stent jail after native coronary stenting is a matter of concern. Attempts at maintaining SB patency can be a technical challenge. The purpose of this study was to determine the clinical impact of SB compromise or occlusion in patients undergoing stenting of parent vessel lesions. We evaluated in-hospital and long-term clinical outcomes (death, Q-wave myocardial infarction, and repeat revascularization rates at 6 months) in 318 consecutive patients undergoing NIR stent implantation across an SB. Based on independent angiographic analysis, 218 (68.6%) patients had no poststent SB compromise, 85 (26.7%) patients had narrowed SB (> 70% narrowing, without total occlusion), and 15 (4.7%) patients had an occluded SB after stent implantation. The baseline patient and lesion characteristics were similar between the groups. Procedural success was 100%. Patients with SB occlusion had a higher stents/lesion ratio (P < 0.006). Side-branch occlusion was associated with higher in-hospital ischemic complications (Q-wave myocardial infarction, 7%; non-Q-wave myocardial infarction, 20%; P < 0.05) compared to patients with SB compromise or normal SB. At 6-month follow-up, there was a trend for more myocardial infarctions in the group with SB occlusion during the index procedure (Q-wave myocardial infarction, 7% vs. 1% in the narrowed and 0% in normal SB; P = 0.09). However, late target lesion revascularization and mortality were similar in the three groups (P = 0.91). SB occlusion after parent vessel stenting is associated with more frequent in-hospital Q-wave and non-Q-wave myocardial infarctions. However, with the NIR stent, side-branch compromise or occlusion does not influence late (6 month) major adverse events, including death, myocardial infarction, or need for repeat revascularization., (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 31 条
[1]   LONG-TERM OUTCOME OF TRANSIENT, UNCOMPLICATED IN-LABORATORY CORONARY-ARTERY CLOSURE [J].
ABDELMEGUID, AE ;
WHITLOW, PL ;
SAPP, SK ;
ELLIS, SG ;
TOPOL, EJ .
CIRCULATION, 1995, 91 (11) :2733-2741
[2]   Defining the appropriate threshold of creatine kinase elevation after percutaneous coronary interventions [J].
Abdelmeguid, AE ;
Ellis, SG ;
Sapp, SK ;
Whitlow, PL ;
Topol, EJ .
AMERICAN HEART JOURNAL, 1996, 131 (06) :1097-1105
[3]   Significance of mild transient release of creatine kinase-MB fraction after percutaneous coronary interventions [J].
Abdelmeguid, AE ;
Topol, EJ ;
Whitlow, PL ;
Sapp, SK ;
Ellis, SG .
CIRCULATION, 1996, 94 (07) :1528-1536
[4]   First International New Intravascular Rigid-Flex Endovascular Stent Study (FINESS): Clinical and angiographic results after elective and urgent stent implantation [J].
Almagor, Y ;
Feld, S ;
Kiemeneij, F ;
Serruys, PW ;
Morice, MC ;
Colombo, A ;
Macaya, C ;
Guermonprez, JL ;
Marco, J ;
Erbel, R ;
Penn, IM ;
Bonan, R ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (04) :847-854
[5]   SIDE BRANCH OCCLUSION DURING CORONARY ANGIOPLASTY - INCIDENCE, ANGIOGRAPHIC CHARACTERISTICS, AND OUTCOME [J].
ARORA, RR ;
RAYMOND, RE ;
DIMAS, AP ;
BHADWAR, K ;
SIMPFENDORFER, C .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 18 (04) :210-212
[6]  
Baim DS, 1996, CATHETER CARDIO DIAG, V37, P314, DOI 10.1002/(SICI)1097-0304(199603)37:3<314::AID-CCD22>3.0.CO
[7]  
2-G
[8]   Stent jail: A minimum-security prison [J].
Caputo, RP ;
Chafizadeh, ER ;
Stoler, RC ;
Lopez, JJ ;
Cohen, DJ ;
Kuntz, RE ;
Carrozza, JP ;
Baim, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (14) :1226-&
[9]  
Carlier SG, 1999, CATHETER CARDIO INTE, V47, P361, DOI 10.1002/(SICI)1522-726X(199907)47:3<361::AID-CCD26>3.3.CO
[10]  
2-5