Digital tomosynthesis of the chest: Utility for detection of lung metastasis in patients with colorectal cancer

被引:39
作者
Jung, H. N. [2 ]
Chung, M. J. [1 ,2 ]
Koo, J. H. [2 ]
Kim, H. C. [3 ]
Lee, K. S. [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Surg, Seoul 135710, South Korea
关键词
MAXIMUM-INTENSITY-PROJECTION; PULMONARY NODULES; CURATIVE RESECTION; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; FOLLOW-UP; CARCINOMA; SENSITIVITY; SURVEILLANCE; RADIOGRAPHY;
D O I
10.1016/j.crad.2011.08.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
AIM: To evaluate the performance of digital tomosynthesis (DT) of the chest for detection of lung nodules in patients with colorectal cancer (CRC). MATERIALS AND METHODS: The institutional review board approved this study, and all patients provided informed consent. A commercial caesium iodide/amorphous silicon (CsI/a-Si) flat-panel detector system was used to verify the performance of the DT and chest radiography (XR) methods. DT was performed in 142 patients with CRC. All 142 patients underwent chest computed tomography (CT) within a week of DT. As a reference standard, two radiologists reviewed the chest CT in consensus and recorded the presence of pulmonary nodules. Another two radiologists independently observed the DT images and recorded the presence of pulmonary nodules. The status of all lung nodules was assessed either histologically or by follow-up over a period of 1 year. The nodules were classified into metastasis, benign, and uncertain. Statistical analysis of the results was performed. RESULTS: Two hundred and thirty-seven nodules from 142 patients were found at CT. These included 71 proven metastases and 126 benign nodules; 40 nodules were uncertain. Observers detected 83% of all lung nodules and 93% of proven metastases using DT. Among 237 nodules, 147 nodules were larger than 4 mm in diameter on the CT images. Observers detected 87% of lung nodules that were larger than 4 mm. CONCLUSION: Despite a reasonably low radiation dose, DT is a sensitive method, and is comparable to chest CT for the detection of lung nodules, particularly metastatic lung nodules in patients with CRC. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 30 条
[1]
Multi Slice Computed Tomography in the study of pulmonary metastases [J].
Angelelli, G. ;
Grimaldi, V. ;
Spinelli, F. ;
Scardapane, A. ;
Sardaro, A. .
RADIOLOGIA MEDICA, 2008, 113 (07) :954-967
[2]
BECK JR, 1986, ARCH PATHOL LAB MED, V110, P685
[3]
Colorectal cancer surveillance: 2005 update of an American Society of Clinical Oncology practice guideline [J].
Desch, CE ;
Benson, A ;
Somerfield, MR ;
Flynn, PJ ;
Krause, C ;
Loprinzi, CL ;
Minsky, BD ;
Pfister, DG ;
Virgo, KS ;
Petrelli, NJ .
JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (33) :8512-8519
[4]
Diederich S, 2006, Cancer Imaging, V6, pS42, DOI 10.1102/1470-7330.2006.9004
[5]
Digital tomosynthesis of the chest for lung nodule detection: Interim sensitivity results from an ongoing NIH-sponsored trial [J].
Dobbins, James T. ;
McAdams, H. Page ;
Song, Jae-Woo ;
Li, Christina M. ;
Godfrey, Devon J. ;
DeLong, David M. ;
Paik, Sang-Hyun ;
Martinez-Jimenez, Santiago .
MEDICAL PHYSICS, 2008, 35 (06) :2554-2557
[6]
Chest tomosynthesis: Technical principles and clinical update [J].
Dobbins, James T., III ;
McAdams, H. Page .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) :244-251
[7]
Tomosynthesis imaging: At a translational crossroads [J].
Dobbins, James T., III .
MEDICAL PHYSICS, 2009, 36 (06) :1956-1967
[8]
Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[9]
New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1) [J].
Eisenhauer, E. A. ;
Therasse, P. ;
Bogaerts, J. ;
Schwartz, L. H. ;
Sargent, D. ;
Ford, R. ;
Dancey, J. ;
Arbuck, S. ;
Gwyther, S. ;
Mooney, M. ;
Rubinstein, L. ;
Shankar, L. ;
Dodd, L. ;
Kaplan, R. ;
Lacombe, D. ;
Verweij, J. .
EUROPEAN JOURNAL OF CANCER, 2009, 45 (02) :228-247
[10]
Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383