The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure

被引:102
作者
Jakicic, JM
Winters, C
Lagally, K
Ho, J
Robertson, RJ
Wing, RR
机构
[1] Univ Pittsburgh, Sch Med, Obes Nutr Res Ctr, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Sch Med, Human Energy Res Lab, Pittsburgh, PA 15213 USA
关键词
exercise; caloric expenditure; reliability; validity; activity monitoring;
D O I
10.1097/00005768-199905000-00020
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study examined the reliability and validity of the TriTrac-R3D triaxial accelerometer to estimate energy expenditure during various modes of exercise. Methods: Twenty subjects (age = 21.5 +/- 3.4 yr; body mass index = 23.3 +/- 3.6 kg.m(-2)) performed five exercises (treadmill walking, treadmill running, stepping, stationary cycling, and slideboard), with each lasting 20-30 min and workload increased at 10-min intervals. To test the inter-TriTrac reliability, two TriTrac-R3D accelerometers were worn during each exercise period, and to examine validity, a simultaneous measurement of energy expenditure was made using indirect calorimetry (SensorMedics 2900 Metabolic Cart). Results: Results showed a significant correlation between the two TriTrac-R3D accelerometers during all exercises. The difference in estimated energy expenditure between the two accelerometers during the walking, stepping, and slideboard exercises was less than 1 kcal.min(-1) but statistically significant (P < 0.05). There was also a significant correlation between energy expenditure estimated by each of the TriTrac-R3D accelerometers and indirect calorimetry during walking, running, stepping, and slideboard exercise (P < 0.05). The interaction of Method X Workload was significant (P < 0.05) for each exercise, indicating that the TriTrac-R3D underestimates energy expenditure and that the magnitude of this underestimation increases as workload increases. Conclusions: Therefore, energy expenditure estimated via triaxial accelerometry does not increase with increasing workloads. These results suggest that there are limitations to using triaxial accelerometry to quantify energy expenditure.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 13 条
  • [1] American College of Sports Medicine, 1995, ACSMS GUID EX TEST P, P14
  • [2] BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
  • [3] Daily physical activity assessment: Comparison between movement registration and doubly labeled water
    Bouten, CVC
    VerboeketVandeVenne, WPHG
    Westerterp, KR
    Verduin, M
    Janssen, JD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) : 1019 - 1026
  • [4] *HEM INC, 1993, TRITR R3D RES ERG OP
  • [5] Accuracy of self-reported exercise and the relationship with weight loss in overweight women
    Jakicic, JM
    Polley, BA
    Rena, RR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (04) : 634 - 638
  • [6] JAKICIC JM, 1995, INT J OBESITY, V19, P893
  • [7] MEIJER GA, 1989, MED SCI SPORT EXER, V21, P343
  • [8] METHODS TO ASSESS PHYSICAL-ACTIVITY WITH SPECIAL REFERENCE TO MOTION SENSORS AND ACCELEROMETERS
    MEIJER, GAL
    WESTERTERP, KR
    VERHOEVEN, FMH
    KOPER, HBM
    TENHOOR, F
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) : 221 - 229
  • [9] *METR LIF INS CO, 1983, NUTR ATHL PERF VAL I
  • [10] MONTOYE HJ, 1983, MED SCI SPORT EXER, V15, P403