Optimisation of the extraction of arsenic species from mussels with low power focused microwaves by applying a Doehlert design

被引:50
作者
Dagnac, T
Padró, A
Rubio, R
Rauret, G
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
[2] Univ Barcelona, Serv Cient, E-08028 Barcelona, Spain
[3] Univ Barcelona, Serv Tecn, E-08028 Barcelona, Spain
关键词
arsenic speciation; liquid chromatography; inductively coupled plasma mass spectrometry; focused microwaves; extraction; Doehlert design;
D O I
10.1016/S0003-2670(98)00179-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The extraction of arsenic species from mussel tissues :is performed by using low power focused microwaves. The arsenic compounds are separated with anion-exchange liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS). The extraction is optimised by applying a sequential Doehlert design, which allows us to quantify the influence of the microwave power, the exposure time and the relative proportions of methanol/water in the extraction medium. Well correlated second-order models are fitted to determine the extraction yields of arsenobetaine (AsBet), a probable arsenosugar (AsS), monomethylarsonate (MMA), dimethylarsinate (DMA) and As (V). By using focused microwaves the time of sample preparation is much shorter than in other methods. At powers close to 40 W with exposure times less than 4 min in methanol/water (55/45), the whole extraction yield reaches 85%. The proportion of species with respect to the total arsenic is 68% of AsBet, 14% of AsS+MMA and 2% of DMA, (C) 1998 Elsevier Science B.V.
引用
收藏
页码:19 / 30
页数:12
相关论文
共 33 条
[1]   ARSENIC SPECIATION IN MARINE BIOLOGICAL-MATERIALS BY LC-UV-HG-ICP/OES [J].
ALBERTI, J ;
RUBIO, R ;
RAURET, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :415-419
[2]   EXTRACTION METHOD FOR ARSENIC SPECIATION IN MARINE ORGANISMS [J].
ALBERTI, J ;
RUBIO, R ;
RAURET, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :420-425
[3]  
AMRAN A, 1995, QUALITY ASSURANCE EN, P285
[4]  
[Anonymous], 1972, DISCRETE MATH, DOI DOI 10.1016/0012-365X(72)90011-8
[5]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[6]   Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry [J].
Corr, JJ ;
Larsen, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1215-1224
[7]   DIRECT COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TO MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY VIA VOLATILE-SPECIES GENERATION AND ITS APPLICATION TO MERCURY AND ARSENIC SPECIATION [J].
COSTAFERNANDEZ, JM ;
LUNZER, F ;
PEREIROGARCIA, R ;
SANZMEDEL, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (11) :1019-1025
[8]   THE BIOTRANSFORMATION OF MONOMETHYLARSONATE AND DIMETHYLARSINATE INTO ARSENOBETAINE IN SEAWATER AND MUSSELS [J].
CULLEN, WR ;
NELSON, JC .
APPLIED ORGANOMETALLIC CHEMISTRY, 1993, 7 (05) :319-327
[9]  
DAGNAC T, IN PRESS TALANTA
[10]  
Doehlert D.H., 1970, Appl. Stat, V19, P231