Root canal preparation with Endo-Eze AET:: changes in root canal shape assessed by micro-computed tomography

被引:48
作者
Paqué, F
Barbakow, F
Peters, OA
机构
[1] Univ Zurich, Dept Prevent Dent Periodontol & Cariol, Div Endodontol, CH-8028 Zurich, Switzerland
[2] Univ Calif San Francisco, Sch Dent, Dept Prevent & Restorat Dent Sci, Endodont Div, San Francisco, CA 94143 USA
关键词
canal shape; Endo-Eze AET; micro-computed tomography; transportation;
D O I
10.1111/j.1365-2591.2005.00968.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the relative performance of Endo-Eze Anatomic Endodontic Technology (AET) stainless steel instruments when shaping maxillary molar root canals in vitro. Methodology Extracted human maxillary molars were scanned, before and after root canal shaping with Endo-Eze AET, employing micro-computed tomography (mu CT) at an isotropic resolution of 34 mu m. Three-dimensional root canal models were reconstructed and evaluated for volume, surface area, 'thickness' (diameter), canal transportation and prepared surface. Preparation errors such as apical zips, perforations and fractured instruments were visually determined from those models. Means were contrasted using ANOVA and Scheffepost-hoc tests. Results Volume and surface area increased significantly and similarly in mesiobuccal (mb), distobuccal (db) and palatal (p) canals and gross preparation errors (n = 17) were found. Mean root canal diameters, 5 mm coronal to the apex, increased from 0.31 to 0.52, 0.35 to 0.50 and 0.50 to 0.70 mm for mb, db and p canals, respectively. Mean canal transportation ranged from 0.15 to 0.29, 0.15 to 0.27 and 0.21 to 0.33 mm for apical, middle and coronal root canal levels, respectively, with highest values found for mb canals (P < 0.003). Root canals were significantly straightened during preparation (P < 0.002). Conclusions In summary, Endo-Eze AET instruments shaped root canals in maxillary molars with substantial canal transportation, particularly in mesiobuccal root canals. Preparation with this instrument removed high volumes of dentine, even though apical preparation was size 30. Based on the current results, Endo-Eze AET cannot be recommended for the preparation of teeth with curved root canals.
引用
收藏
页码:456 / 464
页数:9
相关论文
共 29 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[2]  
Allison D A, 1979, J Endod, V5, P298, DOI 10.1016/S0099-2399(79)80078-3
[3]   A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography [J].
Bergmans, L ;
Van Cleynenbreugel, J ;
Wevers, M ;
Lambrechts, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :390-398
[4]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[5]  
BYSTROM A, 1981, SCAND J DENT RES, V89, P321
[6]  
BYSTROM A, 1987, Endodontics and Dental Traumatology, V3, P58
[7]   A 3-DIMENSIONAL STUDY OF CANAL CURVATURES IN THE MESIAL ROOTS OF MANDIBULAR MOLARS [J].
CUNNINGHAM, CJ ;
SENIA, ES .
JOURNAL OF ENDODONTICS, 1992, 18 (06) :294-300
[8]   Comparing apical preparations of root canals shaped by nickel-titanium rotary instruments and nickel-titanium hand instruments [J].
Deplazes, P ;
Peters, O ;
Barbakow, F .
JOURNAL OF ENDODONTICS, 2001, 27 (03) :196-202
[9]   A reconstructed computerized tomographic comparison of Ni-Ti rotary GT™ files versus traditional instruments in canals shaped by novice operators [J].
Gluskin, AH ;
Brown, DC ;
Buchanan, LS .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (06) :476-484
[10]   Root-canal preparation with FlexMaster:: canal shapes analysed by micro-computed tomography [J].
Hübscher, W ;
Barbakow, F ;
Peters, OA .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (11) :740-747