Effect of the cord pretension of the Dynesys dynamic stabilisation system on the biomechanics of the lumbar spine: a finite element analysis

被引:64
作者
Liu, Chien-Lin [2 ]
Zhong, Zheng-Cheng [1 ]
Hsu, Hung-Wei [1 ]
Shih, Shih-Liang [3 ]
Wang, Shih-Tien [2 ]
Hung, Chinghua [4 ]
Chen, Chen-Sheng [1 ]
机构
[1] Natl Yang Ming Univ, Dept Phys Therapy & Assist Technol, Taipei 112, Taiwan
[2] Taipei Vet Gen Hosp, Dept Orthopaed Surg, Taipei, Taiwan
[3] Taipei City Hosp, Dept Orthopaed Surg, Taipei, Taiwan
[4] Natl Chiao Tung Univ, Taipei, Taiwan
关键词
Lumbar spine; Biomechanics; Dynesys dynamic stabilisation system; Finite element method; Cord pretension; IN-VITRO; ADJACENT; DISC; NEUTRALIZATION; DECOMPRESSION; SEGMENTS; STENOSIS; FUSION;
D O I
10.1007/s00586-011-1817-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
The Dynesys dynamics stabilisation system was developed to maintain the mobility of motion segment of the lumbar spine in order to reduce the incidence of negative effects at the adjacent segments. However, the magnitude of cord pretension may change the stiffness of the Dynesys system and result in a diverse clinical outcome, and the effects of Dynesys cord pretension remain unclear. Displacement-controlled finite element analysis was used to evaluate the biomechanical behaviour of the lumbar spine after insertion of Dynesys with three different cord pretensions. For the implanted level, increasing the cord pretension from 100 to 300 N resulted in an increase in flexion stiffness from 19.0 to 64.5 Nm/deg, a marked increase in facet contact force (FCF) of 35% in extension and 32% in torsion, a 40% increase of the annulus stress in torsion, and an increase in the high-stress region of the pedicle screw in flexion and lateral bending. For the adjacent levels, varying the cord pretension from 100 to 300 N only had a minor influence on range of motion (ROM), FCF, and annulus stress, with changes of 6, 12, and 9%, respectively. This study found that alteration of cord pretension affects the ROM and FCF, and annulus stress within the construct but not the adjacent segment. In addition, use of a 300 N cord pretension causes a much higher stiffness at the implanted level when compared with the intact lumbar spine.
引用
收藏
页码:1850 / 1858
页数:9
相关论文
共 22 条
[1]
Biomechanical comparison between lumbar disc arthroplasty and fusion [J].
Chen, Shih-Hao ;
Zhong, Zheng-Cheng ;
Chen, Chen-Sheng ;
Chen, Wen-Jer ;
Hung, Chinghua .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) :244-253
[2]
Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion [J].
Cheng, Boyle C. ;
Gordon, Jeff ;
Cheng, Joseph ;
Welch, William C. .
SPINE, 2007, 32 (23) :2551-2557
[3]
Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro [J].
Freudiger, S ;
Dubois, G ;
Lorrain, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (3-4) :127-132
[4]
Effects of Charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol [J].
Goel, VK ;
Grauer, JN ;
Patel, TC ;
Biyani, A ;
Sairyo, K ;
Vishnubhotla, S ;
Matyas, A ;
Cowgill, I ;
Shaw, M ;
Long, R ;
Dick, D ;
Panjabi, MM ;
Serhan, H .
SPINE, 2005, 30 (24) :2755-2764
[5]
Clinical experience with the Dynesys semirigid fixation system for the lumbar spine - Surgical and patient-oriented outcome in 50 cases after an average of 2 years [J].
Grob, D ;
Benini, A ;
Junge, A ;
Mannion, AF .
SPINE, 2005, 30 (03) :324-331
[6]
Influence of Dynesys System Screw Profile on Adjacent Segment and Screw [J].
Liu, Chien-Lin ;
Zhong, Zheng-Cheng ;
Shih, Shih-Liang ;
Hung, Chinghua ;
Lee, Yong-Eng ;
Chen, Chen-Sheng .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (06) :410-417
[7]
Non-fusion technology in degenerative lumbar spinal disorders: facts, questions, challenges [J].
Mayer, HM ;
Korge, A .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S85-S91
[8]
Rationale, principles and experimental evaluation of the concept of soft stabilization [J].
Mulholland, RC ;
Sengupta, DK .
EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) :S198-S205
[9]
The effect of dynamic posterior stabilization on facet joint contact forces [J].
Niosi, Christina A. ;
Wilson, Derek C. ;
Zhu, Qingan ;
Keynan, Ory ;
Wilson, David R. ;
Oxland, Thomas R. .
SPINE, 2008, 33 (01) :19-26
[10]
Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study [J].
Niosi, Christina A. ;
Zhu, Qingan A. ;
Wilson, Derek C. ;
Keynan, Ory ;
Wilson, David R. ;
Oxland, Thomas R. .
EUROPEAN SPINE JOURNAL, 2006, 15 (06) :913-922