The last generation of pericardial valves in the aortic position: Ten year follow-up in 589 patients

被引:59
作者
Aupart, MR
Sirinelli, AL
Diemont, FF
Meurisse, YA
Dreyfus, XB
Marchand, MA
机构
[1] Department of Cardiac Surgery, Trousseau University Hospital, Tours
[2] Unite de Chirurgie Cardiaque, Hopital Trousseau
关键词
D O I
10.1016/0003-4975(95)00953-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The first generation of pericardial valves has been withdrawn from the market because of excessively high rates of premature failure. With its original design, the Carpentier-Edwards pericardial valve has promised improved results. Methods. In our institution, 589 patients underwent an isolated aortic valve replacement with a Carpentier-Edwards pericardial bioprosthesis between July 1984 and December 1993. The patients' mean age was 67.5 +/- 11.2 years, and 49% of the patients were in New York Heart Association clinical class III or IV. The operative mortality rate was 2.3% (14 of 595). All patients but 4 were followed up for an average of 4.1 years after their operation, and total follow-up was 2,408 patient-years. Results. At the time of the study, more than 85% of the patients were in New York Heart Association class I or II. There were 79 late deaths. After 10 years, the actuarial survival rate was 71% +/- 7%. Nineteen patients died of valve-related causes (3 endocarditis, 7 thromboembolic complications, 1 structural failure, and 8 sudden deaths). The actuarial rate of freedom from valve-related death was 94% +/- 3% at 10 years. Valve-related complications included 23 thromboembolic episodes (0.9% per patient-year), 14 endocarditis (0.5% per patient-year), 9 reoperations (0.4% per patient-year), and 4 structural valve failures with calcification and stenosis (0.2% per patient-year). After 10 years, freedom from valve-related complications was 84% +/- 6%, from reoperation 97% +/- 2%, and from valve failure 96% +/- 4%. Conclusions. Because of its low rate of valve-related events at 10 years and low rate of structural deterioration with no leaflet tears, this prosthesis is an outstanding choice for patients who need tissue valves and for patients aged 60 years or older.
引用
收藏
页码:615 / 620
页数:6
相关论文
共 29 条
[1]   THE INFLUENCE OF AGE ON THE DURABILITY OF CARPENTIER-EDWARDS BIOLOGICAL VALVES - 13 YEARS FOLLOW-UP [J].
ALKHAJA, N ;
BELBOUL, A ;
RASHID, M ;
ELGATIT, A ;
ROBERTS, D ;
LARSSON, S ;
WILLIAMOLSSON, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (12) :635-640
[2]   THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - INTERMEDIATE RESULTS IN 420 PATIENTS [J].
AUPART, M ;
NEVILLE, P ;
DREYFUS, X ;
MEURISSE, Y ;
SIRINELLI, A ;
MARCHAND, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (05) :277-280
[3]  
AUPART M, 1994, NEW HORIZON FUTURE H, P123
[4]  
Barratt-Boyes B G, 1993, J Heart Valve Dis, V2, P604
[5]   LONG-TERM FOLLOW-UP OF PATIENTS WITH THE ANTIBIOTIC-STERILIZED AORTIC HOMOGRAFT VALVE INSERTED FREEHAND IN THE AORTIC POSITION [J].
BARRATTBOYES, BG ;
ROCHE, AHG ;
SUBRAMANYAN, R ;
PEMBERTON, JR ;
WHITLOCK, RML .
CIRCULATION, 1987, 75 (04) :768-777
[6]   12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES [J].
BLOOMFIELD, P ;
WHEATLEY, DJ ;
PRESCOTT, RJ ;
MILLER, HC .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) :573-579
[7]   FAILURE OF HANCOCK PERICARDIAL XENOGRAFTS - IS PROPHYLACTIC BIOPROSTHETIC REPLACEMENT JUSTIFIED [J].
BORTOLOTTI, U ;
MILANO, A ;
GUERRA, F ;
MAZZUCCO, A ;
MOSSUTO, E ;
THIENE, G ;
GALLUCCI, V .
ANNALS OF THORACIC SURGERY, 1991, 51 (03) :430-437
[8]  
BURDON TA, 1992, J THORAC CARDIOV SUR, V103, P238
[9]  
Butchart E G, 1995, J Heart Valve Dis, V4, P1
[10]  
COSGROVE DM, 1985, J THORAC CARDIOV SUR, V89, P358