Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases

被引:326
作者
Goldberg, SN
Solbiati, L
Hahn, PF
Cosman, E
Conrad, JE
Fogle, R
Gazelle, GS
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[2] Osped Gen, Dept Radiol, Busto Arsizio, Italy
[3] Radion Inc, Burlington, MA USA
关键词
liver neoplasms; therapy; radiofrequency (RF) ablation;
D O I
10.1148/radiology.209.2.9807561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To evaluate whether coagulation necrosis achievable with radio-frequency (RF) ablation can be increased by using a cluster of closely spaced electrodes. MATERIALS AND METHODS: RF was applied to ex vivo liver (n = 68), in vivo liver (n = 12), and in vivo muscle (n = 15) by using a cluster array of three separate internally cooled electrodes spaced 0.5 cm apart. The diameter of coagulation necrosis achieved with optimal RF deposition (1,400-2,150 peak mA) for 5-60 minutes of RF application was determined for electrode tip lengths of 1.5-3.0 cm and compared with that obtained by using a single electrode and otherwise-similar technique. Ten patients with solitary intrahepatic colorectal metastases were also treated by using cluster electrode RF ablation. RESULTS: In ex vivo liver, simultaneous RF application to electrode clusters for 15 30, and 45 minutes produced 4.7 cm +/- 0.1, 6.2 cm +/- 0.1, and 7.6 cm +/- 0.1 of coagulation necrosis, respectively. In in vivo liver and muscle, RF applied to electrode clusters for 12 minutes yielded 3.1 cm +/- 0.2 and 7.6 cm +/- 0.4 of coagulation, respectively. RF application to a single electrode produced maximal coagulation of 2.9 cm in ex vivo liver, 1.8 cm in in vivo liver, and 4.3 cm in muscle (P < .01, all tissues). In colorectal metastases, a single 12-15-minute application of RF to an electrode cluster induced 4.5-7.0 cm of coagulation necrosis. CONCLUSION: Simultaneous RF application to a cluster of three closely spaced internally cooled electrodes enables a larger volume of coagulation in ex vivo liver, in vivo tissues, and hepatic colorectal metastases than previously reported.
引用
收藏
页码:371 / 379
页数:9
相关论文
共 27 条
[1]
HEPATIC METASTASES - INTERSTITIAL LASER PHOTOCOAGULATION WITH REAL-TIME US MONITORING AND DYNAMIC CT EVALUATION OF TREATMENT [J].
AMIN, Z ;
DONALD, JJ ;
MASTERS, A ;
KANT, R ;
STEGER, AC ;
BOWN, SG ;
LEES, WR .
RADIOLOGY, 1993, 187 (02) :339-347
[2]
ANZAI Y, 1995, AM J NEURORADIOL, V16, P39
[3]
THEORETICAL ASPECTS OF RADIOFREQUENCY LESIONS IN THE DORSAL-ROOT ENTRY ZONE [J].
COSMAN, ER ;
NASHOLD, BS ;
OVELMANLEVITT, J .
NEUROSURGERY, 1984, 15 (06) :945-950
[4]
Goldberg S. N., 1997, AJR S, V168, P121
[5]
GOLDBERG SN, 1995, ACAD RADIOL, V2, P670
[6]
Percutaneous radiofrequency tissue ablation: Does perfusion-mediated tissue cooling limit coagulation necrosis? [J].
Goldberg, SN ;
Hahn, PF ;
Tanabe, KK ;
Mueller, PR ;
Schima, W ;
Athanasoulis, CA ;
Compton, CC ;
Solbiati, L ;
Gazelle, GS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) :101-111
[7]
Ablation of liver tumors using percutaneous RF therapy [J].
Goldberg, SN ;
Gazelle, GS ;
Solbiati, L ;
Livraghi, T ;
Tanabe, KK ;
Hahn, PF ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :1023-1028
[8]
GOLDBERG SN, 1995, ACAD RADIOL, V2, P399
[9]
Goldberg SN, 1996, ACAD RADIOL, V3, P636
[10]
Goldberg SN, 1997, RADIOLOGY, V205, P258