Determination of the single component and competitive adsorption isotherms of the 1-indanol enantiomers by the inverse method

被引:91
作者
Felinger, A
Zhou, DM
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
基金
匈牙利科学研究基金会; 美国国家科学基金会;
关键词
adsorption isotherms; inverse method of isotherm determination; chiral stationary phases; LC; 1-indanol; cellulose tribenzoate;
D O I
10.1016/S0021-9673(03)00889-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The inverse method of isotherm determination consists in calculating the numerical values of the coefficients of an isotherm model that give a set of chromatographic profiles in best possible agreement with the set of experimental profiles available. This method was applied to determine the adsorption isotherms of the 1-indanol enantiomers on a cellulose tribenzoate chiral stationary phase. Both single-component and competitive isotherms were determined by using no more than one or two overloaded band profiles. The isotherms determined from the overloaded band profiles agreed extremely well with the isotherms determined by frontal analysis. Several isotherm models were used and tested. The best-fit isotherm was selected by means of statistical evaluation of the results. The results show that the adsorption is best characterized with a model describing heterogeneous adsorption with bimodal adsorption energy distribution. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 49
页数:15
相关论文
共 21 条
[1]   Application of gradients in the simulated moving bed process [J].
Antos, D ;
Seidel-Morgenstern, A .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (23) :6667-6682
[2]  
CAVAZZINI A, UNPUB J CHROMATOGR A
[3]   Kinetic and equilibrium study of the enantioseparation of fenoprofen in a batch setup [J].
Ching, CB ;
Arlt, W ;
Lisso, M ;
Wozny, G .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (11) :4365-4369
[4]   DETERMINATION OF ISOTHERMS FROM CHROMATOGRAPHIC PEAK SHAPES [J].
DOSE, EV ;
JACOBSON, S ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :833-839
[5]   RAPID SIMULATION OF CHROMATOGRAPHIC BAND PROFILES ON PERSONAL COMPUTERS [J].
FELINGER, A ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 658 (02) :511-515
[6]   Numerical determination of the competitive isotherm of enantiomers [J].
Felinger, A ;
Cavazzini, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) :207-225
[7]  
Felinger A., 1998, DATA ANAL SIGNAL PRO
[8]   Adsorption isotherms of nonionic surfactants in SBA-15 measured by micro-column chromatography [J].
Findenegg, G. H. ;
Eltekov, A. Y. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) :236-240
[9]  
GOTMAR G, UNPUB ANAL CHEM
[10]   THEORETICAL-STUDY OF THE ACCURACY AND PRECISION OF THE MEASUREMENT OF SINGLE-COMPONENT ISOTHERMS BY THE ELUTION BY CHARACTERISTIC POINT METHOD [J].
GUAN, H ;
STANLEY, BJ ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :27-41